器件描述

控制器 adapter for h7e-N

参数
制造商: Omron
产品种类: 控制器
RoHS:

Y92F-77B器件文档内容

                                         R                                                                H7EC

Self-Powered Count Totalizer

Subminiature Total Counters With
Improved Appearance and Features

H Large display with 8.6 mm (0.338 in) height
H Available with backlit LCD
H PNP/NPN DC voltage input available
H Eight-digits, counting range 0 to 99999999
H Key-protect switch to prevent front resetting
H Selectable input speed: 30 Hz or 1 kHz

    (except for AC/DC multi-voltage input
    models)

H NEMA 4/IP66 front
H Replaceable battery
H New black case

Ordering Information

  TOTAL COUNTERS

Count input                Max. counting speed          Display             Part number
PNP/NPN universal DC       30 Hz or 1 kHz (Selectable)  7-segment LCD with  H7EC-NV-BH
voltage input                                           backlight
                                                        7-segment LCD       H7EC-NV-B
AC/DC multi-voltage input  20 Hz                        7-segment LCD       H7EC-NFV-B

No-voltage                 30 Hz or 1 kHz (Selectable) 7-segment LCD        H7EC-N-B

MODEL NUMBER LEGEND

1. Count Input                                             2. Display
None: No-voltage input                                             None: 7-segment LCD without backlight
V:          PNP/NPN universal DC voltage input                     H:       7-segment LCD with backlight
FV: AC/DC multi-voltage input

3. Case Color
B:          Black

J ACCESSORIES (ORDER SEPARATELY)

Item                                            26 mm � 45 mm               Part number
Replacement Battery                             24.8 mm � 48.8 mm           Y92S-36
Wire-wrap Terminal (set of two Terminals)                                   Y92S-37
Flush Mounting Adapter                                                      Y92F-75
                                                                            Y92F-77B

                                                        1
H7EC                                                                                                                       H7EC

Specifications

GENERAL

Item                       H7EC-NV-B                      H7EC-NFV-B                                     H7EC-N-B
                           H7EC-NV-BH
Operating mode
Mounting method            Up type
External connections
Reset                      Flush mounting
Number of digits
Count input                Screw terminals, optional Wire-wrap Terminals (See Note 1.)

Display                    External/Manual reset
Max. counting speed
Case color                 8
Attachment
Approved standard          PNP/NPN universal DC voltage AC/DC multi-voltage input                        No-voltage input
                           input

                           7-segment LCD with or without backlight (character height: 8.6 mm) (See Note 2.)

                           30 Hz/1 kHz                    20 Hz                                          30 Hz/1 kHz

                           black

                           Waterproof packing, flush mounting bracket

                           UL508, CSA C22.2 No.14, Lloyds
                           Conforms to EN61010-1/IEC61010-1 (Pollution degree2/overvoltage category III)
                           Conforms to VDE0106/P100

Note: 1. Wire-wrap Terminals (Y92S-37) can be ordered separately.
          2. Only PNP/NPN universal DC voltage input models (-H models) are available with a backlight.

J RATINGS

Item                       H7EC-NV-B                      H7EC-NFV-B                                     H7EC-N-B
Supply voltage             H7EC-NV-BH
                           Backlight model: 24 VDC (only  Not required (powered by battery)
Count input                for backlight)
                           No-backlight model: Not        High (logic) level: 24 to                      No voltage input
Reset input                required (powered by battery)  240 VAC/VDC, 50/60 Hz                          Maximum short-circuit
                           High (logic) level: 4.5 to     Low (logic) level: 0 to 2.4 VAC/               impedance: 10 k max.
Max. counting speed        30 VDC                         VDC, 50/60 Hz                                  Short-circuit residual voltage:
(see Note.)                Low (logic) level: 0 to 2 VDC  No voltage input                               0.5 V max.
Minimum signal width       (Input impedance: Approx.      Maximum short-circuit                          Minimum open impedance:
Reset system               4.7 k)                         impedance: 10 k max.                           750 k min.
Terminal screw tightening                                 Short-circuit residual voltage:                30 Hz or 1 kHz (Selectable)
torque                     30 Hz or 1 kHz (Selectable)    0.5 V max.
Ambient Temperature                                       Minimum open impedance:
Ambient humidity                                          750 k min.
                                                          20 Hz

                           20 Hz: 25 ms
                           30 Hz: 16.7 ms
                           1 kHz: 0.5 ms
                           External reset and manual reset: Minimum signal width of 20 ms
                           0.98 N S m max.

                           Operating: --10�C to 55�C (14�F to 131�F) with no condensation or icing
                           Storage: --25�C to 65�C (--13�F to 149�F) with no condensation or icing
                           Operating: 25% to 85%

Note: ON/OFF ratio 1:1

                                                  2
H7EC                                                                                                             H7EC

J CHARACTERISTICS

Item                       H7EC-NV-B                        H7EC-NFV-B                       H7EC-N-B
Insulation resistance      H7EC-NV-BH

Dielectric strength        100 M min. (at 500 VDC)          100 M min. (at 500 VDC)          100 M min. (at 500 VDC)
                           between current-carrying metal   between current-carrying metal   between current-carrying metal
Impulse withstand voltage  parts and exposed non-current    parts and exposed non-current    parts and exposed non-current
                           carrying metal parts, and        carrying metal parts and         carrying metal parts
Noise immunity             between the backlight power      between count input terminals
                           supply terminal and count input  and reset terminals
Static immunity            terminals/reset terminals for
Vibration resistance       backlight models
Shock resistance
Battery life               1,000 VAC, 50/60 Hz for 1 min    3,700 VAC, 50/60 Hz for 1 min    1,000 VAC, 50/60 Hz for 1 min
EMC                        between current-carrying metal   between current-carrying metal   between current-carrying metal
                           parts and exposed non-current    parts and exposed non-current    parts and exposed non-current
Enclosure rating           carrying metal parts and         carrying metal parts             carrying metal parts
Weight (See Note.)         between the backlight power      2,200 VAC, 50/60 Hz for 1 min
                           supply terminal and count input  between reset terminals and      4.5 kV between current-carrying
                           terminals/reset terminals for    exposed non-current-carrying     terminal and exposed
                           backlight models                 metal parts and between count    non-current-carrying metal
                           4.5 kV between current-carrying  input terminals and reset        parts
                           terminal and exposed             terminals                        �500 V in normal mode, �1.5
                           non-current-carrying metal       4.5 kV between current-carrying  kV in command mode
                           parts                            terminal and exposed
                           Between input terminals: �600    non-current-carrying metal
                           V in normal mode, �1.5 kV in     parts
                           command mode                     3 kV between input terminals
                           For backlight power supply       and reset terminals
                           (backlight model): �480 V in     Between count input terminals:
                           normal mode, �1.5 kV in          �1.5 kV in normal mode, �1.5
                           command mode                     kV in command mode
                                                            Between reset input terminals:
                                                            �500 V in normal mode, �1.5
                                                            kV in command mode

                           �8 kV (malfunction)
                           Malfunction: 0.35-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
                           Destruction: 0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
                           Malfunction: 200 m/s2 3 times each in 6 directions
                           Destruction: 300 m/s2 3 times each in 6 directions

                           7 years min. with continuous input at 25�C (lithium battery)

                           (EMI)                            EN50081-1
                           Emission Enclosure:              EN55022 class B
                           (EMS)                            EN50082-2
                           Immunity ESD:                    EN61000-4-2: 4-kV contact discharge (level 2)
                                                                          8-kV air discharge (level 3)
                           Immunity RF-interference from AM Radio Waves:
                                                            ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3)
                           Immunity RF-interference from Pulse-modulated Radio Waves:
                                                            ENV50204: 10 V/m (900 MHz � 5 MHz) (level 3)
                           Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz ) (level 3)
                           Immunity Burst:                  EN61000-4-4: 2-kV power line (level 3)
                                                                          2-kV I/O signal line (level 4)

                           Front panel:     IP66, NEMA4
                           Terminal block:  IP20

                           Non-backlight model: Approx.     Approx. 60 g                     Approx. 60 g
                           60 g
                           Backlight model: Approx. 65 g

Note: Weight includes waterproof packing and panel mounting bracket.

                                                3
H7EC                                                                                                       H7EC

Nomenclature                                  Front view

J TOTAL COUNTER

                                                                      Reset Key
                                                                      Reset the count value. Not operable
                                                                      under key-protect.

Counting speed switch                                                 Key-protect Switch
For all models except for H7EC-NFV-j
If the switch setting is changed, press the                             Setting    Key-protect
Reset Key on the front panel.                                         (see note)

                                                                      Front panel

  Setting     Counting speed                                                              OFF
(see note)           30 Hz                                                         (default setting)

Front panel  (default setting)               Bottom view

                                                                                                 ON

                                                                      Terminal block

                                  1 kHz

           Terminal block

Note: Perform switch setting before mounting to a control panel.

Operation                                              Full-scale
                                              (Full-scale
J OPERATING MODES                             --1)

    H7EC Total Counter

    Incrementing Operation
    (Up)

                                       Reset
                                Count input

                   Counting display values

                                                                   4
H7EC                                                                                                                                                    H7EC

Dimensions                                                                                                                     Panel Cutout
                                                                                                                               Separate mounting
Unit: mm (inch)
                                                                                                                                                     60 min.
J H7EC-N

                                                                                       44.8
                                                                                      (1.76)

                                                                                                                               60 min.

                              24                                                                                         22             45  +0.5
                            (0.94)                                                                                     (0.87)                 0

                                                                                                                                                  22.2       +0.5
                                                                                                                                                               0

                                             48                                                                 48.5           Joint mounting
                                           (1.89)                                                              (1.91)
                                                                                                37                                                                 +10
                                                                                              (1.46)                                        (48   �Units  -  2.5)   0

Dimensions with Flush Mounting Bracket                                                                                                                                  22.2  +0.5
                                                                                                                                                                                0

                                                                                                                               Waterproofing is not possible
                                                                                                                               for joint mounting

                              35                                                                                               � When mounting, insert the Counter into
                            (1.38)
                                                                                                                                   the cutout. Insert the adapter from the
                                                                                                                                   back and push in the Counter while
                                                                                                                                   making the gap between the front panel
                                                                                                                                   and the cutout panel as small as
                                                                                                                                   possible. Use screws to secure the
                                                                                                                                   Counter. If waterproofing is desired,
                                                                                                                                   insert the waterproof packing.

                                                                                                                               � When several Counters are installed,

                                                                                                                                   ensure that the ambient temperature
                                                                                                                                   will not exceed specifications.

                                                                                                                               � The appropriate thickness of the panel

                                                                                                                                   is 1 to 5 mm.

Installation

J TERMINAL ARRANGEMENT

Bottom view: View of the Total Counter rotated horizontally 180�

Backlight Model             Non-backlight Model

                 Backlight
                 24 VDC

Count  Reset                        Count  Reset
input  input                        input  input

                                                                                              5
H7EC                                                                                                                                        H7EC

Connections

J PNP/NPN UNIVERSAL DC VOLTAGE                               2. Solid-state Input
    INPUT MODEL WITH BACKLIGHT
                                                                       Open collector of a
   1. Contact Input (Input by a Relay or Switch Contact)               PNP transistor

Relay             Backlight  Relay                                                              Input                  Open collector of a
                  24 VDC                                                                               Backlight PNP transistor
                                                                                                       24 VDC
           Input  Reset                                                                                Reset

or Switch                    or Switch

                                                             or Open collector of an                   or Open collector of an
                                                             NPN transistor                            NPN transistor

                                                             Note: 1.    Terminals 2 and 4 (input circuit and reset circuit) are
                                                                     2.  functionally isolated.

                                                                         Select input transistors according to the following:
                                                                                      Dielectric strength of the collector  50 V
                                                                                      Leakage current < 1 �A

                                                          6
H7EC                                                                                                                                                  H7EC

J PNP/NPN UNIVERSAL DC VOLTAGE                                             J NO-VOLTAGE INPUT MODEL
    INPUT MODEL WITHOUT BACKLIGHT

1. Contact Input (Input by a Relay or Switch Contact)                      1. Contact Input (Input by a Relay or Switch Contact)

       Relay                                      Relay                           Relay                        Input  Reset  Relay

                 Input              Reset

      or Switch                            or Switch                              or Switch                    Terminals 2 and 4 are
                                                                                                               internally connected.

                                                                                                                                           or Switch

2. Solid-state Input                            Open collector of a        Note:  Use Relays and Switches that have high contact reli-
                                                PNP transistor                    ability because the current flowing from terminals 1 or
         Open collector of a        Reset                                         3 is as small as approx. 10 �A. OMRON's G3TA-IA/ID
         PNP transistor                                                           is recommended as the SSR.

                             Input

                                                                                  2. Solid-state Input
                                                                                      (Open Collector Input of an NPN Transistor)

                                                                                  Open collector of an                       Open collector of an
                                                                                  NPN transistor                             NPN transistor
                                                                                                        Input         Reset

      or Open collector of an              or Open collector of an
      NPN transistor                       NPN transistor

                                                                                                        Terminals 2 and 4 are
                                                                                                        internally connected. or Switch

                                                                           Note:  1. Residual voltage in the output section of Proximity
                                                                                      Sensors or Photoelectric Sensors becomes less than
Note:  1. Terminals 2 and 4 (input circuit and reset circuit) are                     0.5 V because the current flowing from terminals 1 or 3
           functionally isolated.                                                     is as small as approx. 10 �A, allowing easy
                                                                                      connection.
       2. Select input transistors according to the following:
                 Dielectric strength of the collector  50 V                       2. Select input transistors according to the following:
                 Leakage current < 1 �A                                                     Dielectric strength of the collector  50 V
                                                                                            Leakage current < 1 �A

J AC/DC MULTI-VOLTAGE INPUT MODEL

       Relay

                 Input                     Reset         Relay

      or Switch                                   or Switch

                                                  or Open collector of
                                                  an NPN transistor

                                                                        7
H7EC                                                                                                                                    H7EC

Accessories (Order Separately)

An H7EC is supplied with a mounting bracket and nut. In addition, the Flush Mounting Adapters shown here allow the H7EC to be fitted to
existing panel cutouts.

J Y92F-75 FLUSH MOUNTING ADAPTER
    FOR 26 � 45 RECTANGULAR CUTOUT

Must be used with mounting bracket supplied with the Counter

        31    24.2  22.2                                               Two 3.5 dia. mounting holes                Panel Cutout
      (1.22)                                                                                   26
                                                                                                                                         Two M3
                                         45.2                                               (1.02)
                                         48.2                                          4                   26
                                                                                                                                     45
                                          63                                                                                         63
                                          72
                                        (2.83)                                                                                     (2.48)

J Y92F-77B FLUSH MOUNTING ADAPTER                                                                                       Panel cutout
    FOR 24.8 � 48.8 RECTANGULAR CUTOUT

Must be used with mounting bracket supplied with the Counter

                          28.8    24.2  22.2                                                                24.8
                          (1.13)                                                                           (0.98)

                                                                       45.2                4                                     48.8
                                                                                                                                (1.92)
                                                                       48.2
                                                                       53.8
                                                                       (2.12)

J Y92S-37 WIRE-WRAP TERMINAL                                                        44.8            Wire-wrap terminal
    (SET OF TWO TERMINALS)                                                         (1.76)           (1 � 1 mm)

                                                                         24                                                             22
                                                                       (0.94)

                                                                                     48                25  48.5 65.6            17.1
                                                                                   (1.89)
                                                                                                                        (2.58)

The wire--wrap terminals have a cross sectional dimension of                 Wire                 Bit          Sleeve              Wrapped
1x1 mm. Select one of three guages of wire from the table at                                                                         state
right. Also listed in the table is the appropriate wiring hardware     AWG22               2-A             2-B
                                                                       AWG24               1-A             1-B                  Normal
                                                                       AWG26               1-B             1-B                  Normal
                                                                                                                                Normal

                                                                    8
H7EC                                                                                                                H7EC

J Y92S-36 REPLACEMENT (LITHIUM)
    BATTERY (3 V)

                                                             24.5 dia.

7.7

Precautions                                                                J BEFORE USE

     ! WARNING                                                             An insulation sheet has been inserted to maintain the quality of
                                                                           the Totalizer in the event of a long period without use. Be sure to
   This product has a built-in lithium battery. Do not short-circuit       remove this sheet before attempting to use the product.
   the + and -- terminals, charge, disassemble, deform, or expose          Remove the insulation sheet and press the Reset Key on the
   the battery to fire. The battery may explode (break), catch fire,       front panel of the Counter. (With the H7ER-N,-NV(-H),-NV1(-H),
   or cause liquid leakage.                                                models, "0" or "0.0" will be displayed after 1 s.)

     ! Caution                                                                                            Insulation Sheet

   Do not use any battery other than the specified one (Y92S-36).                                        Reset Key
   Using another battery may cause liquid leakage or breakage,
   resulting in malfunction or injury.                                     Switch settings on the Counter must be performed before
                                                                           mounting it to a control panel.
     ! Caution
                                                                           Do not use the Counter in locations subject to:
   If a voltage other than the rated one is applied, internal              SSevere changes in temperature.
   elements may be damaged.                                                SCondensation as the result of high temperatures.
   Do not use the Counter in the following places:

  � Locations subject to direct sunlight.
  � Locations subject to corrosive gases.
  � Locations subject to dust.

                                                                           J MOUNTING PRECAUTIONS FOR FLUSH
                                                                               MOUNTING

                                                                           Although the operating section is watertight (conforming to
                                                                           NEMA4, IP66), rubber packing is provided to avoid water leakage
                                                                           through the gap between the Counter and panel cutout. Unless
                                                                           this rubber packing is tightly squeezed on, water may permeate
                                                                           inside the panel. For this reason, be sure to tighten the screws
                                                                           for fixing the Flush Mounting Bracket.

                                                                           Screw for the Flush Mounting Bracket

                                                                           The wider side must  Adapter  Adapter screw section
                                                                           face the panel.
                                                                                                                  0.5 to 1 mm

                                                                           Panel                         Tighten the screw until the
                                                                                                         distance is within the range
                                                                                                         shown above.

                                                                        9
H7EC                                                                                                                  H7EC

J RESET INPUT AND COUNT INPUT                                        J COUNT INPUT OR RESET INPUT TO
                                                                         MORE THAN ONE H7E COUNTER AT
The H7EC operates using its built-in Battery. If the H7EC is             A TIME
connected to a device that has +V and OUT terminals that are
connected with a diode as shown in the circuit diagram, the          PNP/NPN Universal DC Voltage Input
circuit indicated by the arrow 1 or 2 will be formed when the
device is turned OFF. As a result, the H7EC may be reset or
count by one. It is recommended that such devices not be
connected to the H7EC.

Icinrtceruintal                   Count input                                                   or

                                  or reset input

If an excessive voltage is applied to the count or reset input                                      or
terminals, the internal elements may be damaged.

Ensure that the following voltages are not exceeded:

SPNP/NPN universal voltage input model: 30 VDC                       Note:  H (Reset ON) level must be 4.5 V minimum.

SAC/DC voltage input model:                                                 H=   4.7 (k)/N + V
                 At count input:  240 VAC (peak voltage: 338V)                   4.7 (k)/N + R
                                  240 VDC
                 At reset input:  3 VDC (no-voltage input)           No-voltage Input

                 No-voltage input model: 3 VDC

Do not remove the outer case when voltage is being applied to                                                          or
the power supply terminals or to the input terminals.

The input for the H7Ej-NFV-j is a high-impedance circuit so          Note: 1.    The leakage current of the transistor used for input
influence from an induced voltage may result in malfunction.                 2.  must be less than 1 �A.
When the input signal wiring is longer than 10 m (stray
capacitance of 120 pF/m, at room temperature), a CR filter or a                  The forward voltage of the diode must be as low as
bleeder resistor should be connected.                                            possible (i.e., 0.1 V maximum with an IF of 20 �A) so
                                                                                 the voltage between terminals 3 and 4 will be 0.5 V
                                                                                 when the reset input is ON.

                                                                 10
H7EC                                                                                              H7EC

J INPUT AND POWER SUPPLY                                           J BATTERY REPLACEMENT

Do not apply voltage on the Counter if the Counter is a model      Remove the wiring when replacing the Battery. Do not come in
that operates with no-voltage input, to avoid damaging the         contact with any item to which high voltage is being applied.
internal circuit of the Counter.                                   Doing so may result in electric shock.
Do not connect any single input signal in parallel to Counter
models operating with no-voltage input and those operating with    Before changing the Battery, be sure that you are not carrying
voltage input, otherwise the Counters may malfunction.             any static electric charge.
When connecting a sensor to the Counter that operates with
no-voltage input, make sure that the sensor has open collector     Procedure for replacing the Battery (refer to the diagrams below):
output.
                                                                      1. Using the tool, pry open the lift-tab on the case. (1)
Sensor                                                               2. Pull the body out of its outer case. (2)
                                                                      3. Lift the Battery up by the edge and remove it. (3)
The operation of the Counter may be affected if the line voltage
of the power supply exceeds 500 pF (about 10 m, with parallel              When removing the Battery, do not come in contact with the
wires of 2 x 2 mm). Keep all wires as short as possible. When              display area or any internal parts.
using shielded wire, stray capacitance may occur.                     4. Wipe the back of the new Battery before inserting it.
When connecting an open collector input from a transistor to the      5. Ensure that the + and -- terminals are correctly oriented.
Counter that operates with no-voltage input, make sure that the       6. After replacing the Battery, re-insert the body into its case. (4)
leakage current of the transistor is 5 �A maximum.                         Check that the case is securely held in by the lift-tab.
When connecting count input from an SSR to the Counter that           7. Press the Reset Key before use (not necessary for
operates with AC/DC voltage input, use OMRON's G3TA-IA or                  H7ER-N,-NV,-NV1). (5)
G3TA-ID SSR. Otherwise, make sure that the leakage current of      When the internal Battery nears expiration, the display may
the SSR is 0.1 mA maximum or connect a bleeder resistor in         flicker.
parallel to the input circuit of the Counter.
                                                                   (1)  Tool                 (2)

or  Leakage current:                                                    (1)
                                                                                        (3)
    0.1 mA max.
                                                                                 (4)
    or

       or                                                                  (5)
          *Bleeder resistor
          The voltage between terminals 1 and 2 must be            J EN/IEC STANDARDS
          1.5 V maximum when the SSR is OFF.
                                                                   The counter input, reset input, and backlight power supply
J BACKLIGHT POWER SUPPLY                                           terminals of the no-voltage input or PNP/NPN universal DC
                                                                   voltage input models (H7Ej-N,-N1, H7Ej-NV(-H),-NV1(-H)) are
To reduce variation in the brightness of the backlight when using  not isolated.
more than one H7E with a backlight, use the same power supply      A SELV power supply conforming to Appendix H of IEC61010-1
for all the backlights.                                            should be used for the counter input, reset input and backlight
                                                                   power supply terminals. A SELV power supply is a power supply
When connecting the DC power supply for the backlights, be         for which the input and output have double or reinforced
sure to connect the polarities correctly.                          insulation, and for which the output voltage is 30 Vrems with 42.4
                                                                   V peak or 60 VDC max. (Only the H7Ej-NVj-H has a
                                                                   backlight.)
                                                                   The terminals for counter input and reset input for AC/DC
                                                                   multi-voltage input models have basic insulation.
                                                                   Connect the reset input terminals to a device that does not have
                                                                   exposed current-carrying parts and has basic insulation for
                                                                   240 VAC.

                                                            11
H7EC                                                                                      H7EC

NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.

                                     R  OMRON ON--LINE                                    OMRON CANADA, INC.

OMRON ELECTRONICS LLC                   Global -- http://www.omron.com                    885 Milner Avenue
                                        USA -- http://www.omron.com/oei                   Scarborough, Ontario M1B 5V8
One East Commerce Drive                 Canada -- http://www.omron.com/oci
Schaumburg, IL 60173                                                                      416-286-6465

1-800-55-OMRON

Cat. No. GC TMCN1  3/02                 Specifications subject to change without notice.  Printed in U.S.A.

                                                       12
This datasheet has been downloaded from:
            datasheet.sonata9.com

                 Free Download
           Daily Updated Database
      100% Free Datasheet Search Site
  100% Free IC Replacement Search Site
     Convenient Electronic Dictionary

               Fast Search System
             www.sonata9.com

                                                 All Datasheets Cannot Be Modified Without Permission
                                                                Copyright � Each Manufacturing Company
小广播

技术资料推荐

论坛推荐

技术视频推荐

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 sonata9.com, Inc. All rights reserved

北京pk10 幸运时时彩官网 幸运时时彩 一分时时彩官网 大发时时彩 山东群英会app下载 幸运时时彩平台 安徽快3 亿信彩票主页 幸运时时彩平台