E52-CA15AY D=1.6 2M

器件型号:E52-CA15AY D=1.6 2M
器件类别:机电产品    工业自动化    控制器   
厂商名称:OMRON
厂商官网:
下载文档

器件描述

控制器 T-COUPLE TYPE K L=15CM 2M

参数
产品属性属性值
制造商:Omron
产品种类:控制器
发货限制:Mouser目前不销售该产品。
商标:Omron Automation and Safety
产品类型:Controllers
工厂包装数量:1
子类别:Controllers
零件号别名:E52CA15AYD162M

E52-CA15AY D=1.6 2M器件文档内容

Temperature Sensor

E52

                                                                                                                                CSM_E52_DS_E_16_1

A Wide Variety of High-precision

Temperature Sensors

• New and improved E52 temperature sensor series.

Wide selection of sensors compatible with M3 screws

• Ideal for the thermal input devices of Temperature Controllers.

• Select from a wide variety of Temperature Sensors according

to the temperature to be measured, location, and environment,

and also according to the type and shape of the terminal.

Refer to Safety Precautions for All Temperature

Controllers.

Ordering Information

■ List of Models

Classifi-  Descrip-    Model and appearance                     Tempera-       Element  Conduc-        Class  Protective        Terminal    Page

cation     tion                                                 ture range     type     tor type              tubing            type

                                                                (See note 3.)                                 material

General-   Sheathed    E52-P@AY                                 −196°C to      Pt100    3-conduc-   B         SUS316            Exposed     5

purpose    platinum                                             450°C                   tor system                              lead wires

Models     resistance  E52-P@C-N                                −200°C to                                     ASTM316L          Enclosed    6

           thermom-                                             450°C                                                           terminals

           eter        E52-P@B-N                                                                                                Exposed

                                                                                                                                terminals

           Standard    E52-P@C-N                                0°C to 450°C                                  SUS316            Enclosed    7

           platinum                                                                                                             terminals

           resistance

           thermom-

           eter

           Sheathed    E52-CA@AY                                0°C to 900°C   K (CA)   Non-        2 (0.75)  ASTM316L          Exposed     9 to

           thermo-     E52-IC@AY                                               J (IC)   grounded                                lead wires  12

           couple                                                                       type

                       E52-CA@B-N                                                                                               Exposed     13

                       E52-IC@B-N                                                                                               terminals

                       E52-CA@C-N                                                                                               Enclosed

                       E52-IC@C-N                                                                                               terminals

           Standard    E52-CA@B-N                                                                             SUS316            Exposed     14

           thermo-     E52-IC@B-N                                                                                               terminals

           couple      E52-CA@C-N                                                                                               Enclosed    15

                       E52-IC@C-N                                                                                               terminals

                       E52-PR@C-N                               0°C to         R (PR)               2 (0.25)  JIS ceramic       Enclosed    16

                                                                1,400°C                                       JIS special       terminals

                                                                                                              ceramic

Low-cost   Low-cost    E52-P10AEY                               0°C to 250°C   Pt100    3-conduc-   B         SUS316            Exposed     17

Models     platinum                                                                     tor system                              lead wires

           resistance  E52-P6DY                                 −50°C to                                      SUS304

           thermom-                                             250°C

           eter        E52-P6FY

           Low-cost    E52-CA@ASY                               0°C to 400°C   K (CA)   Non-        2 (0.75)                                18

           thermo-     E52-IC@ASY                                              J (IC)   grounded

           couple                                                                       type

                       E52-CA1DY                                                        Grounded                                            19

                       E52-IC1DY                                                        type

                       E52-CA6F-N                                                                                                           20

                       E52-IC6F-N

                       E52-CA6D-N

                       E52-IC6D-N

                       E52-CA10AE-N                                                     Non-

                       E52-IC10AE-N                                                     grounded

                                                                                        type

Note: 1.  Exclusive models are provided on the following page.

2.        These tables provide general specifications only. Be sure to read the detailed specifications and precautions before  use.

3.        The temperature range varies with the material, thickness, construction, and element type of the protective tubing.

                                                                                                                                                   1
                                                                                                                                             E52

Classifi-    Descrip-     Model and      appearance  Tempera-       Element               Conduc-        Class  Protective       Terminal    Page

cation           tion                                ture range     type                  tor type                   tubing      type

                                                     (See note 3.)                                              material

Exclusive    Bayonet      E52-CA2GVY                 0°C to 350°C   K (CA)                Grounded    2 (0.75)  SUS304           Exposed     21

Models       spring for   E52-IC2GVY                                J (IC)                type                                   lead wires

             molding

             machines

             Crimping     E52-CA1GTY                 0°C to 300°C                                               ---

             terminals    E52-IC1GTY

             Used for     E52-P2GSY                  −50°C to       Pt100                 3-conduc-   B         SUS304

             measur-                                 250°C                                tor system

             ing surface

             tempera-

             tures

             Used for     E52-P10GRY                 −50°C to                                                                                22

             room tem-                               60°C

             perature

             measure-

             ment

             Double-el-   E52-CA20AY-7               0°C to 900°C   K (CA)                Two non-    2 (0.75)  ASTM316L                     25

             ement                                                                        grounded

             model                                                                        types

                          E52-P20AY-7                −196°C to      Pt100                 Two 3-con-  B

                                                     250°C                                ductor

                                                                                          systems

                          E52-P20C-N-7               −200°C to                                                                   Enclosed    26

                                                     450°C                                                                       terminals

             Water-       E52-P10GPY                 0°C to 70°C                          3-conduc-             SUS304           Exposed     22

             proof mod-                                                                   tor system                             lead wires

             el

                          E52-P5AY-40                −50°C to                                                   Fluororesin                  23

                                                     180°C                                                      tubing

             Corrosion-   E52-P20AY-1                −80°C to

             resistant                               180°C

             model

                          E52-CA20AY-1               0°C to 180°C   K (CA)                Non-        2 (0.75)

                                                                                          grounded

                                                                                          type

             Silicone-    E52-CA1DY-40               0°C to 300°C                         Grounded              SUS304                       26

             covered                                                                      type

             lead wires

                          E52-CA1GTY-14              0°C to 200°C                                               ---

             Explosion-   E52-P@@C-N-6               ---            Pt100                 3-conduc-   B         ASTM316L         Enclosed    24

             proof mod-                                                                   tor system                             terminals

             el

                          E52-CA@@C-N-6              ---            K (CA)                Non-        2 (0.75)

                                                                                          grounded

                                                                                          type

Thermistors               E52-THE5A                  −50°C to       Ther-                 Element-    1         SUS304           Exposed     28

                          E52-THE6F                  300°C          mistor                inter-                                 lead wires

                          E52-THE6D                                                       change-

                                                                                          able

                                                                                          thermistor

Note: 1.   General-purpose models and low-cost models are provided on the previous page.

2.         These tables provide general specifications only. Be sure to read the detailed specifications and precautions before  use.

3.         The temperature range varies with the material, thickness, construction, and element type of the protective tubing.

                                                                                                                                                   2
                                                                                                                                       E52

■ Accessories

It is recommended that the following accessories  be used for mounting  Temperature Sensors.

Accessory     Temperature                                               Mounting example                                               Page

              range

Compression   600°C max.   Mounting with                                                                                               29

Fitting                    Compression                                  Terminal box

                           Fitting                Compression Fitting

                                                  PT screw

                                                  Welding               Protective tubing     Note:  The Compression Fitting is not

                                                                                                     of airtight construction. Do not

                                                                                                     use the Compression Fitting for

                                                                                                     applications in which the

                                                                                                     exposure of the sensing object

                                                                                                     will cause problems.

Loose Flange  400°C max.   Mounting with                                                      Note:  1.  Use the Loose Flange in

                           Loose Flange                                                                  normal atmospheric

                                                  Loose Flange          Terminal box                     pressure. The Loose

                                                  Mounting screw        Protective tubing                Flange is not of airtight

                                                                                                         construction.

                                                                                                     2.  Use the Loose Flange at

                                                                                                         400°C max.

                                                                                                     3.  Do not apply the Loose

                                                                                                         Flange to protective tubing

                                                                                                         diameters other than the

                                                                                                         applicable ones.

                                                                                                                                             3
                                                                                                                                                 E52

General-purpose Models

■ Model Number Legend

The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.

Platinum Resistance Thermometers

E52-@@@ D=@@@M

         1  2  3  4  56

1.  Element type                                                     4.  Diameter

    P: Pt100                                                             3.2: 3.2-mm dia. (Protective tubing construction: Sheathed)

2.  Protective tubing length (L)                                              E52-@@AY and E52-@@C-N only

    Specify the length in centimeters within the following range:        4.8: 4.8-mm dia. (Protective tubing construction: Sheathed)

    Unit (cm)                                                                 E52-@@AY and E52-@@C-N only

    E52-@@AY                                                             6.4: 6.4-mm dia. (Protective tubing construction: Sheathed)

                                                                              E52-@@AY and E52-@@C-N only

    Diameter (D)     Length (L)                                          8:   8-mm dia. (Protective tubing construction: Sheathed)

    3.2              7 to 100                                                 E52-@@B-N and E52-@@C-N only

    4.8              10 to 600                                           10:  10-mm dia. (Protective tubing construction: Standard)

    6.4              13 to 1,300                                              E52-@@C-N only

                                                                     5.  Heat resistance

    E52-@@B-N                                                                 Code                Temperature range                   Lead type

    Diameter (D)     Length (L)                                          ---                      −20°C to 70°C              Vinyl-covered

    8                20 to 100                                                                    Sleeve: 0°C to 70°C

    E52-@@C-N                                                            NETU                     0°C to 180°C               Glass-wool-covered,

                                                                                                  Sleeve: 0°C to 100°C       externally shielded with

    Diameter (D)     Length (L)                                                                                              stainless

    3.2              12 to 100                                           Specify for E52-@@AY model only.

    4.8              15 to 600                                       6.  Lead length (M)

    6.4              18 to 1,300                                         Specify the length in meters within the following range for the E52-

    8                21 to 100                                           @@AY only:

                                                                         Range: 0.5, 1 to 100 m

    10               26 to 100

3.  Terminal

    AY:     Exposed lead wires (Y-type crimp terminal for M3.5)

    B-N: Exposed terminals

    C-N: Enclosed terminals

Examples

Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm,  heat  resistive,     lead  length:  10  m

            E52-P42AY D=4.8 NETU 10M

■ Sheathed Platinum Resistance Thermometers

Refer to Model Number Legend above for the Pt100.

Specifications

Element type                    Pt100

Class                           JIS class B

Sheath material                 SUS316 (E52-P@AY)

                                ASTM316L (E52-P@B-N, E52-P@C-N)

Sheath outer diameter           3.2 dia., 4.8 dia., 6.4 dia., 8 dia

Conductor type                  3-conductor system

Temperature range               −200°C to 450°C (in dry air)

                                                                                                                                                       4
                                                                                                                                                           E52

Exposed-lead Models

E52-P@AY

Dimensions

           Y-type crimp terminal for M3.5                                               Unit (mm)                   Lead Wire

               Maker tube                     SUS304 sleeve  Sheath (SUS316)            D              d     l      •  Standard (−20°C to 70°C):

Red (A)                    Lead wire                                                                                   Fully vinyl-covered with twelve 0.18-dia

White (B)                                  d                                  D         3.2 dia.       8     40        conductors (0.3 mm thick) and 4.8 mm

                           M                                 L                          4.8 dia.       8     40        in outer dia. The sleeve resists a

Black (B)                                                                               6.4 dia.       8     40        temperature range between 0°C and

                                                                                                                       70°C.

                                                                                                                    •  Heat Resistive (0°C to 180°C):

                                                                                                                       Fully glass-wool-covered with thirty

                                                                                                                       0.12-dia. conductors (0.3 mm thick)

                                                                                                                       externally shielded with stainless steel,

                                                                                                                       4 mm in outer dia. The sleeve resists a

                                                                                                                       temperature range between 0°C and

                                                                                                                       100°C.

                                                                                                                    •  Lead Wire Length (M): 1, 2, 4, or 8 m

Model Information

Custom-made models are available           on request. Refer to page 4 for    details.

Terminal type  Protective                  Protective        Lead wire                                    Lead wire length M (m)

               tubing                 tubing length          type             1                           2                    4                       8

               diameter D                  L (cm)

                   (mm)                                                                                          Model

Exposed-lead   3.2 dia.               15               Standard         E52-P15AY       D=3.2      E52-P15AY D=3.2     E52-P15AY  D=3.2  E52-P15AY D=3.2

Models                                                                  1M                         2M                  4M                8M

                                                       Heat resistive   E52-P15AY       D=3.2      E52-P15AY D=3.2     E52-P15AY  D=3.2  E52-P15AY D=3.2

                                                                        NETU 1M                    NETU 2M             NETU 4M           NETU 8M

                                      20               Standard         E52-P20AY       D=3.2      E52-P20AY D=3.2     E52-P20AY  D=3.2  E52-P20AY D=3.2

                                                                        1M                         2M                  4M                8M

                                                       Heat resistive   E52-P20AY       D=3.2      E52-P20AY D=3.2     E52-P20AY  D=3.2  E52-P20AY D=3.2

                                                                        NETU 1M                    NETU 2M             NETU 4M           NETU 8M

                                      35               Standard         E52-P35AY       D=3.2      E52-P35AY D=3.2     E52-P35AY  D=3.2  E52-P35AY D=3.2

                                                                        1M                         2M                  4M                8M

                                                       Heat resistive   E52-P35AY       D=3.2      E52-P35AY D=3.2     E52-P35AY  D=3.2  E52-P35AY D=3.2

                                                                        NETU 1M                    NETU 2M             NETU 4M           NETU 8M

               4.8 dia.               20               Standard         E52-P20AY       D=4.8      E52-P20AY D=4.8     E52-P20AY  D=4.8  E52-P20AY D=4.8

                                                                        1M                         2M                  4M                8M

                                                       Heat resistive   E52-P20AY       D=4.8      E52-P20AY D=4.8     E52-P20AY  D=4.8  E52-P20AY D=4.8

                                                                        NETU 1M                    NETU 2M             NETU 4M           NETU 8M

                                      35               Standard         E52-P35AY       D=4.8      E52-P35AY D=4.8     E52-P35AY  D=4.8  E52-P35AY D=4.8

                                                                        1M                         2M                  4M                8M

                                                       Heat resistive   E52-P35AY       D=4.8      E52-P35AY D=4.8     E52-P35AY  D=4.8  E52-P35AY D=4.8

                                                                        NETU 1M                    NETU 2M             NETU 4M           NETU 8M

                                      50               Standard         E52-P50AY       D=4.8      E52-P50AY D=4.8     E52-P50AY  D=4.8  E52-P50AY D=4.8

                                                                        1M                         2M                  4M                8M

                                                       Heat resistive   E52-P50AY       D=4.8      E52-P50AY D=4.8     E52-P50AY  D=4.8  E52-P50AY D=4.8

                                                                        NETU 1M                    NETU 2M             NETU 4M           NETU 8M

               6.4 dia.               20               Standard         E52-P20AY       D=6.4      E52-P20AY D=6.4     E52-P20AY  D=6.4  E52-P20AY D=6.4

                                                                        1M                         2M                  4M                8M

                                                       Heat resistive   E52-P20AY       D=6.4      E52-P20AY D=6.4     E52-P20AY  D=6.4  E52-P20AY D=6.4

                                                                        NETU 1M                    NETU 2M             NETU 4M           NETU 8M

                                      35               Standard         E52-P35AY       D=6.4      E52-P35AY D=6.4     E52-P35AY  D=6.4  E52-P35AY D=6.4

                                                                        1M                         2M                  4M                8M

                                                       Heat resistive   E52-P35AY       D=6.4      E52-P35AY D=6.4     E52-P35AY  D=6.4  E52-P35AY D=6.4

                                                                        NETU 1M                    NETU 2M             NETU 4M           NETU 8M

                                      50               Standard         E52-P50AY       D=6.4      E52-P50AY D=6.4     E52-P50AY  D=6.4  E52-P50AY D=6.4

                                                                        1M                         2M                  4M                8M

                                                       Heat resistive   E52-P50AY       D=6.4      E52-P50AY D=6.4     E52-P50AY  D=6.4  E52-P50AY D=6.4

                                                                        NETU 1M                    NETU 2M             NETU 4M           NETU 8M

                                                                                                                                                                  5
                                                                                                                                                       E52

Enclosed-terminal Models

E52-P@C-N

Dimensions

Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.

                   67        15

                                     Socket (SUS304)

   Chain                                       Sheath (ASTM316L)

66                                                                   D

                                     Caulking

                                 Terminal box

    Cap                                        (See note 2.)

G3/8,                  40                      L-35

Packing internal

diameter 6.5 dia.

                                          Use wiring terminals that fit M3 screws.

Terminal box: The permissible temperature is 0°C to 90°C.

Note: 1.      The terminals in the cap indicate polarity (A, B, b).

          2.  The length L is in centimeters, but “35” is 35 millimeters.

              Therefore, for the E52-P35C-N: L = 35 (cm), the sheath length L − 35 = 350 − 35 = 315 mm.

Model Information

Custom-made models are available on request. Refer to page 4 for details.

    Terminal type            Protective                                                Protective tubing diameter D (mm)

                             tubing length            3.2 dia.                         4.8 dia.                         6.4 dia.               8 dia.

                                  L (cm)

                                                                                                         Model

Enclosed-terminal            20                E52-P20C-N D=3.2                        E52-P20C-N D=4.8  E52-P20C-N D=6.4         E52-P20C-N D=8

Models                       35                E52-P35C-N D=3.2                        E52-P35C-N D=4.8  E52-P35C-N D=6.4         E52-P35C-N D=8

                             50                E52-P50C-N D=3.2                        E52-P50C-N D=4.8  E52-P50C-N D=6.4         E52-P50C-N D=8

                             75                ---                                     E52-P75C-N D=4.8  E52-P75C-N D=6.4         ---

Exposed-terminal Models

E52-P@B-N

Dimensions

Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.

                                               Sheath (ASTM316L)                       Model Information

                       42.5      15  Terminal box                                      Custom-made models are available on request. Refer to page 4 for

                                     Socket (SUS304)                                   details

A

B             45                                                                    D  Terminal          Protective     Protective tubing diameter D (mm)

b                                                                                      type              tubing length                 8 dia.

                                     Caulking                                                                   L (cm)

                                                      (See note.)                                                                      Model

    17.6  3-M3                                 L-40

                   Product label                                                       Exposed-          20             E52-P20B-N D=8

Terminal box:      The permissible temperature is 0°C to 100°C.                        terminal          35             E52-P35B-N D=8

                                                                                       Models            50             E52-P50B-N D=8

Note: The length L is in centimeters, but “40” is 40 millimeters.

          Therefore, for the E52-P35B-N: L = 35 (cm), the sheath length L − 40 = 350 − 40 = 310 mm.

                                                                                                                                                            6
                                                                                                                                           E52

■ Standard Platinum Resistance Thermometers

Refer to Model Number Legend on page 4 for the Pt100.

Specifications

Element type                             Pt100

Class                                    JIS class B (See note 2.)

Protective tubing material               SUS316

Conductor type                           3-conductor system

Temperature range                        0°C to 450°C (in dry air)

Note: 1.   Use the sheathed platinum resistance thermometer if

           condensation is likely to result.

       2.  Be sure that the thermometer is free of vibration or shock if

           high temperatures are measured.

Enclosed-terminal Models

E52-P@C-N

Dimensions

Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.

                             96

                                         Terminal box

                                                                    SUS316 protective tubing

    Chain

86                                                                                                                             D

                                         Socket (SUS304)

    Cap                               5

                                                                             (See  note 1.)

           G1/2,                 53                                 L-50

           Packing internal

           diameter 9 dia.

Note: 1.   The length L is in centimeters, but “50” is 50 millimeters.

           Therefore, for the E52-P75C-N: L = 75 (cm), the protective              tubing     length  L  −  50  =  750  −  50  = 700  mm.

Terminal box: The permissible temperature is 0°C to 90°C.

Note: The terminals in the cap indicate polarity (A, B, B).

Model Information

Custom-made models               are available on request.  Refer to page 4 for details.

    Terminal type                    Protective tubing      Protective tubing

                                      length L (cm)         diameter D (mm)

                                                                    10 dia.

                                                                    Model

Enclosed-terminal                35                         E52-P35C-N D=10

Models                           50                         E52-P50C-N D=10

                                 75                         E52-P75C-N D=10

                                 100                        E52-P100C-N D=10

                                                                                                                                                7
                                                                                                                                                  E52

■ Model Number Legend

The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.

Thermocouples

E52-@@@ D=@@@M@

         1  2  3  4  5  6      7

1.  Element type                                                              4.  Diameter

    CA: K                                                                         Specify the protective tubing material according to the table.

    IC: J                                                                         Code         Diameter  Protective tubing         Protective tubing

    PR: R                                                                                      (D)            construction             material

2.  Protective tubing length (L)                                                  1            1 mm      Sheathed               ASTM316L

    Specify the length in centimeters in  the  following  range:  Unit  (cm)      1.6          1.6 mm    Sheathed               ASTM316L

    E52-@@AY (Exposed-lead Model)                                                 3.2          3.2 mm    Sheathed               ASTM316L

    Diameter (D)     Length (L)                                                   4.8          4.8 mm    Sheathed               ASTM316L

    1                2 to 200                                                     6.4          6.4 mm    Sheathed               ASTM316L

    1.6              3 to 500                                                     8            8 mm      Sheathed               ASTM316L

    3.2              5 to 2,000                                                   10           10 mm     Standard               SUS316, SUS310S

    4.8              8 to 2,300                                                   12           12 mm     Standard               SUS316, SUS310S

    6.4              10 to 1,200                                                  15           15 mm     Standard               SUS316, SUS310S

    8                12 to 1,000                                                  22           22 mm     Standard               SUS316, SUS310S

                                                                                  17           17 mm     Standard               PT1, PT0

    E52-@@B-N and E52-@@C-N       (except      E52-PR@C-N)                    5.  Heat resistance

    Diameter (D)     Length (L)                                                   Specify this item for the exposed-lead models only.

    3.2              11 to 2,000                                                  Code         Temperature range                   Lead type

    4.8              14 to 2,300                                                  ---          −20°C to 70°C           Vinyl-covered

    6.4              16 to 1,200                                                               Sleeve: 0°C to 70°C

    8.0              18 to 1,000                                                  NETU         0°C to 150°C            Glass-wool-covered with exter-

    10               21 to 126                                                                 Sleeve: 0°C to 100°C    nal shield of stainless

    12               24 to 126                                                6.  Lead length (M)

    15               29 to 156                                                    Specify the length in meters in the following range for the E52-

    22               39 to 206                                                    @@AY only.

                                                                                  Range: 1 to 100 m

    E52-PR@C-N                                                                7.  Protective tubing material

    Diameter (D)     Length (L)                                                        Code            Protective tubing              Element type

    15               50, 75, 100                                                                             material

3.  Terminal                                                                      ---          ASTM316L                         K, J

    AY:     Exposed lead wires (Y-type crimp terminal for M3.5)                   SUS310S      SUS310S                          K, D = 10 to 22

            (element type: K, J)                                                  PT1          JIS ceramic Cat.1                R

    B-N:    Exposed terminals (element type: K, J)                                PT0          JIS special ceramic              R

    C-N:    Enclosed terminals (element type: K, J, R)

Examples

Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m

            E52-CA42AY D=4.8 NETU 10M

Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2

            E52-IC36C-N D=3.2

                                                                                                                                                       8
                                                                                                                                                                  E52

■ Sheathed Thermocouples

Specifications                                                                                 Permissible Temperature in Dry Air

Element type                                 K (CA), J(IC)                                             D                             Element wire

Class                                        JIS class 2 (0.75)                                                           K (CA)                       J (IC)

                                                                                                                      ASTM316L                     ASTM316L

Thermal contact                              Non-grounded type                                 1 dia.         650°C                        450°C

Sheath material                              CA: ASTM316L                                      1.6 dia.       650°C                        450°C

                                             IC: ASTM316L                                      3.2 dia.       750°C                        650°C

                                                                                               4.8 dia.       800°C                        750°C

                                                                                               6.4 dia.       800°C                        750°C

                                                                                               8.0 dia.       900°C                        750°C

                                                                                               Note: For details on the permissible temperature, refer to page D-5 of

                                                                                                       Introduction of Temperature Controllers (Cat. No. H900).

Exposed-lead               Models

E52-CA@AY

Dimensions

             Y-type crimp terminal for M3.5      SUS304 sleeve                                 Unit (mm)                    Permissible Temperature in Dry        Air

                                                 (See note 2.)  Sheath (ASTM316L)

Red (+)          Lead wire (See note 1.)                                                           D          d       l            D              Element wire

                                                 d                                     D       1 dia.         8       55                           K (CA)

                                                                                               1.6 dia.       8       55                           ASTM316L

White (−)                                                                                                                    1 dia.        650°C

                           M                                     L                             3.2 dia.       8       55

Note: 1.     Lead Wire (Compensating Conductor)                                                4.8 dia.       8       55     1.6 dia.      650°C

             • Standard (−20°C to 70°C):                                                       6.4 dia.       11      55     3.2 dia.      750°C

             Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm                        8 dia.         11      55     4.8 dia.      800°C

             thick) and external dimensions of 2.4 × 4.1.                                                                    6.4 dia.      800°C

             • Heat Resistive (0°C to 150°C):                                                                                8.0 dia.      900°C

             Fully glass-wool-covered with seven 0.3-dia. conductors

             (0.5 mm thick) with external shield of stainless steel and

             external dimensions of 2.8 × 4.6

             The heat-resistive lead wires cannot be used in locations

             exposed to water or other liquids.

             • Lead Wire Length (M): 1, 2, 4, or 8 m

         2.  The sleeve resists temperatures ranging between −20°C and 70°C

             for standard models and 0°C and 100°C for heat-resistive models.

K (CA) Model Information (E52-CA@AY)

Model Information

Custom-made models are available on request.                    Refer to Model   Number Legend on page 8 for details.

Terminal type    Protective                      Protective      Lead wire type                                    Lead wire length M (m)

                 tubing diameter             tubing length L                                1                      2                   4                       8

                 D (mm)                             (cm)

                                                                                                                            Model

Exposed-lead     1 dia.                      15                 Standard           E52-CA15AY D=1 1M      E52-CA15AY D=1 2M  E52-CA15AY    D=1 4M  E52-CA15AY     D=1 8M

Models                                                          Heat resistive     E52-CA15AY D=1         E52-CA15AY D=1     E52-CA15AY    D=1     E52-CA15AY     D=1

                                                                                   NETU 1M                NETU 2M            NETU 4M               NETU 8M

                                             20                 Standard           E52-CA20AY D=1 1M      E52-CA20AY D=1 2M  E52-CA20AY    D=1 4M  E52-CA20AY     D=1 8M

                                                                Heat resistive     E52-CA20AY D=1         E52-CA20AY D=1     E52-CA20AY    D=1     E52-CA20AY     D=1

                                                                                   NETU 1M                NETU 2M            NETU 4M               NETU 8M

                                             35                 Standard           E52-CA35AY D=1 1M      E52-CA35AY D=1 2M  E52-CA35AY    D=1 4M  E52-CA35AY     D=1 8M

                                                                Heat resistive     E52-CA35AY D=1         E52-CA35AY D=1     E52-CA35AY    D=1     E52-CA35AY     D=1

                                                                                   NETU 1M                NETU 2M            NETU 4M               NETU 8M

                 1.6 dia.                    15                 Standard           E52-CA15AY D=1.6       E52-CA15AY D=1.6   E52-CA15AY    D=1.6   E52-CA15AY     D=1.6

                                                                                   1M                     2M                 4M                    8M

                                                                Heat resistive     E52-CA15AY D=1.6       E52-CA15AY D=1.6   E52-CA15AY    D=1.6   E52-CA15AY     D=1.6

                                                                                   NETU 1M                NETU 2M            NETU 4M               NETU 8M

                                             20                 Standard           E52-CA20AY D=1.6       E52-CA20AY D=1.6   E52-CA20AY    D=1.6   E52-CA20AY     D=1.6

                                                                                   1M                     2M                 4M                    8M

                                                                Heat resistive     E52-CA20AY D=1.6       E52-CA20AY D=1.6   E52-CA20AY    D=1.6   E52-CA20AY     D=1.6

                                                                                   NETU 1M                NETU 2M            NETU 4M               NETU 8M

                                             35                 Standard           E52-CA35AY D=1.6       E52-CA35AY D=1.6   E52-CA35AY    D=1.6   E52-CA35AY     D=1.6

                                                                                   1M                     2M                 4M                    8M

                                                                Heat resistive     E52-CA35AY D=1.6       E52-CA35AY D=1.6   E52-CA35AY    D=1.6   E52-CA35AY     D=1.6

                                                                                   NETU 1M                NETU 2M            NETU 4M               NETU 8M

                                                                                                                                                                          9
                                                                                                                                        E52

Terminal type  Protective           Protective     Lead wire type                              Lead wire length M (m)

               tubing diameter  tubing length   L                           1                  2                  4                  8

               D (mm)               (cm)

                                                                                                        Model

Exposed-lead   3.2 dia.         15                 Standard        E52-CA15AY D=3.2   E52-CA15AY D=3.2   E52-CA15AY D=3.2   E52-CA15AY D=3.2

Models                                                             1M                 2M                 4M                 8M

                                                   Heat resistive  E52-CA15AY D=3.2   E52-CA15AY D=3.2   E52-CA15AY D=3.2   E52-CA15AY D=3.2

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

                                20                 Standard        E52-CA20AY D=3.2   E52-CA20AY D=3.2   E52-CA20AY D=3.2   E52-CA20AY D=3.2

                                                                   1M                 2M                 4M                 8M

                                                   Heat resistive  E52-CA20AY D=3.2   E52-CA20AY D=3.2   E52-CA20AY D=3.2   E52-CA20AY D=3.2

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

                                35                 Standard        E52-CA35AY D=3.2   E52-CA35AY D=3.2   E52-CA35AY D=3.2   E52-CA35AY D=3.2

                                                                   1M                 2M                 4M                 8M

                                                   Heat resistive  E52-CA35AY D=3.2   E52-CA35AY D=3.2   E52-CA35AY D=3.2   E52-CA35AY D=3.2

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

                                50                 Standard        E52-CA50AY D=3.2   E52-CA50AY D=3.2   E52-CA50AY D=3.2   E52-CA50AY D=3.2

                                                                   1M                 2M                 4M                 8M

                                                   Heat resistive  E52-CA50AY D=3.2   E52-CA50AY D=3.2   E52-CA50AY D=3.2   E52-CA50AY D=3.2

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

               4.8 dia.         20                 Standard        E52-CA20AY D=4.8   E52-CA20AY D=4.8   E52-CA20AY D=4.8   E52-CA20AY D=4.8

                                                                   1M                 2M                 4M                 8M

                                                   Heat resistive  E52-CA20AY D=4.8   E52-CA20AY D=4.8   E52-CA20AY D=4.8   E52-CA20AY D=4.8

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

                                35                 Standard        E52-CA35AY D=4.8   E52-CA35AY D=4.8   E52-CA35AY D=4.8   E52-CA35AY D=4.8

                                                                   1M                 2M                 4M                 8M

                                                   Heat resistive  E52-CA35AY D=4.8   E52-CA35AY D=4.8   E52-CA35AY D=4.8   E52-CA35AY D=4.8

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

                                50                 Standard        E52-CA50AY D=4.8   E52-CA50AY D=4.8   E52-CA50AY D=4.8   E52-CA50AY D=4.8

                                                                   1M                 2M                 4M                 8M

                                                   Heat resistive  E52-CA50AY D=4.8   E52-CA50AY D=4.8   E52-CA50AY D=4.8   E52-CA50AY D=4.8

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

               6.4 dia.         20                 Standard        E52-CA20AY D=6.4   E52-CA20AY D=6.4   E52-CA20AY D=6.4   E52-CA20AY D=6.4

                                                                   1M                 2M                 4M                 8M

                                                   Heat resistive  E52-CA20AY D=6.4   E52-CA20AY D=6.4   E52-CA20AY D=6.4   E52-CA20AY D=6.4

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

                                35                 Standard        E52-CA35AY D=6.4   E52-CA35AY D=6.4   E52-CA35AY D=6.4   E52-CA35AY D=6.4

                                                                   1M                 2M                 4M                 8M

                                                   Heat resistive  E52-CA35AY D=6.4   E52-CA35AY D=6.4   E52-CA35AY D=6.4   E52-CA35AY D=6.4

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

                                50                 Standard        E52-CA50AY D=6.4   E52-CA50AY D=6.4   E52-CA50AY D=6.4   E52-CA50AY D=6.4

                                                                   1M                 2M                 4M                 8M

                                                   Heat resistive  E52-CA50AY D=6.4   E52-CA50AY D=6.4   E52-CA50AY D=6.4   E52-CA50AY D=6.4

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

               8 dia.           20                 Standard        E52-CA20AY D=8 1M  E52-CA20AY D=8 2M  E52-CA20AY D=8 4M  E52-CA20AY D=8 8M

                                                   Heat resistive  E52-CA20AY D=8     E52-CA20AY D=8     E52-CA20AY D=8     E52-CA20AY D=8

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

                                35                 Standard        E52-CA35AY D=8 1M  E52-CA35AY D=8 2M  E52-CA35AY D=8 4M  E52-CA35AY D=8 8M

                                                   Heat resistive  E52-CA35AY D=8     E52-CA35AY D=8     E52-CA35AY D=8     E52-CA35AY D=8

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

                                50                 Standard        E52-CA50AY D=8 1M  E52-CA50AY D=8 2M  E52-CA50AY D=8 4M  E52-CA50AY D=8 8M

                                                   Heat resistive  E52-CA50AY D=8     E52-CA50AY D=8     E52-CA50AY D=8     E52-CA50AY D=8

                                                                   NETU 1M            NETU 2M            NETU 4M            NETU 8M

                                                                                                                                               10
                                                                                                                                                          E52

Exposed-lead Models

E52-IC@AY

Dimensions

               Y-type crimp terminal for M3.5  SUS304 sleeve                            Unit (mm)                      Permissible Temperature in Dry Air

                                               (See note 2.)  Sheath (ASTM316L)

Red (+)        Lead wire (See note 1.)                                                     D              d   l               D             Element wire

                                                   d                                 D  1 dia.            8   55                            J (IC)

White (−)                                                                               1.6 dia.          8   55                            ASTM316L

                         M                                    L                         3.2 dia.          8   55       1 dia.        450°C

Note: 1.       Lead Wire (Compensating Conductor)                                       4.8 dia.          8   55       1.6 dia.      450°C

               • Standard (−20°C to 70°C):                                              6.4 dia.          11  55       3.2 dia.      650°C

               Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm               8 dia.            11  55       4.8 dia.      750°C

               thick) and external dimensions of 2.4 × 4.1.                                                            6.4 dia.      750°C

               • Heat Resistive (0°C to 150°C):                                                                        8.0 dia.      750°C

               Fully glass-wool-covered with seven 0.3-dia. conductors

               (0.5 mm thick) with external shield of stainless steel and

               external dimensions of 2.8 × 4.6

               The heat-resistive lead wires cannot be used in locations

               exposed to water or other liquids.

               • Lead Wire Length (M): 1, 2, 4, or 8 m

           2.  The sleeve resists temperatures ranging between −20°C and

               70°C for standard models and 0°C and 100°C for heat-resistive

               models.

J (IC) Model Information (E52-IC@AY)

Model Information

Custom-made models are available on request.                  Refer to Model     Number Legend on page 8  for details

Terminal type           Protective             Protective     Lead wire                                      Lead wire length M (m)

                        tubing                 tubing length  type                      1                              2                    4

                        diameter D                    L (cm)

                        (mm)                                                                                           Model

Exposed-lead   1 dia.                          15             Standard           E52-IC15AY D=1 1M        E52-IC15AY D=1 2M          E52-IC15AY D=1 4M

Models                                                        Heat resistive     E52-IC15AY D=1 NETU      E52-IC15AY D=1 NETU        E52-IC15AY D=1 NETU

                                                                                 1M                       2M                         4M

                                               20             Standard           E52-IC20AY D=1 1M        E52-IC20AY D=1 2M          E52-IC20AY D=1 4M

                                                              Heat resistive     E52-IC20AY D=1 NETU      E52-IC20AY D=1 NETU        E52-IC20AY D=1 NETU

                                                                                 1M                       2M                         4M

                                               35             Standard           E52-IC35AY D=1 1M        E52-IC35AY D=1 2M          E52-IC35AY D=1 4M

                                                              Heat resistive     E52-IC35AY D=1 NETU      E52-IC35AY D=1 NETU        E52-IC35AY D=1 NETU

                                                                                 1M                       2M                         4M

               1.6 dia.                        15             Standard           E52-IC15AY D=1.6 1M      E52-IC15AY D=1.6 2M        E52-IC15AY D=1.6 4M

                                                              Heat resistive     E52-IC15AY D=1.6 NETU    E52-IC15AY D=1.6 NETU      E52-IC15AY D=1.6 NETU

                                                                                 1M                       2M                         4M

                                               20             Standard           E52-IC20AY D=1.6 1M      E52-IC20AY D=1.6 2M        E52-IC20AY D=1.6 4M

                                                              Heat resistive     E52-IC20AY D=1.6 NETU    E52-IC20AY D=1.6 NETU      E52-IC20AY D=1.6 NETU

                                                                                 1M                       2M                         4M

                                               35             Standard           E52-IC35AY D=1.6 1M      E52-IC35AY D=1.6 2M        E52-IC35AY D=1.6 4M

                                                              Heat resistive     E52-IC35AY D=1.6 NETU    E52-IC35AY D=1.6 NETU      E52-IC35AY D=1.6 NETU

                                                                                 1M                       2M                         4M

                                                                                                                                                               11
                                                                                                                E52

Terminal type  Protective  Protective     Lead wire                              Lead wire length M (m)

               tubing      tubing length  type                1                      2                       4

               diameter D      L (cm)

               (mm)                                                                  Model

Exposed-lead   3.2 dia.    15             Standard        E52-IC15AY D=3.2 1M    E52-IC15AY D=3.2 2M     E52-IC15AY D=3.2 4M

Models                                    Heat resistive  E52-IC15AY D=3.2 NETU  E52-IC15AY D=3.2 NETU   E52-IC15AY D=3.2 NETU

                                                          1M                     2M                      4M

                           20             Standard        E52-IC20AY D=3.2 1M    E52-IC20AY D=3.2 2M     E52-IC20AY D=3.2 4M

                                          Heat resistive  E52-IC20AY D=3.2 NETU  E52-IC20AY D=3.2 NETU   E52-IC20AY D=3.2 NETU

                                                          1M                     2M                      4M

                           35             Standard        E52-IC35AY D=3.2 1M    E52-IC35AY D=3.2 2M     E52-IC35AY D=3.2 4M

                                          Heat resistive  E52-IC35AY D=3.2 NETU  E52-IC35AY D=3.2 NETU   E52-IC35AY D=3.2 NETU

                                                          1M                     2M                      4M

                           50             Standard        E52-IC50AY D=3.2 1M    E52-IC50AY D=3.2 2M     E52-IC50AY D=3.2 4M

                                          Heat resistive  E52-IC50AY D=3.2 NETU  E52-IC50AY D=3.2 NETU   E52-IC50AY D=3.2 NETU

                                                          1M                     2M                      4M

               4.8 dia.    20             Standard        E52-IC20AY D=4.8 1M    E52-IC20AY D=4.8 2M     E52-IC20AY D=4.8 4M

                                          Heat resistive  E52-IC20AY D=4.8 NETU  E52-IC20AY D=4.8 NETU   E52-IC20AY D=4.8 NETU

                                                          1M                     2M                      4M

                           35             Standard        E52-IC35AY D=4.8 1M    E52-IC35AY D=4.8 2M     E52-IC35AY D=4.8 4M

                                          Heat resistive  E52-IC35AY D=4.8 NETU  E52-IC35AY D=4.8 NETU   E52-IC35AY D=4.8 NETU

                                                          1M                     2M                      4M

                           50             Standard        E52-IC50AY D=4.8 1M    E52-IC50AY D=4.8 2M     E52-IC50AY D=4.8 4M

                                          Heat resistive  E52-IC50AY D=4.8 NETU  E52-IC50AY D=4.8 NETU   E52-IC50AY D=4.8 NETU

                                                          1M                     2M                      4M

               6.4 dia.    20             Standard        E52-IC20AY D=6.4 1M    E52-IC20AY D=6.4 2M     E52-IC20AY D=6.4 4M

                                          Heat resistive  E52-IC20AY D=6.4 NETU  E52-IC20AY D=6.4 NETU   E52-IC20AY D=6.4 NETU

                                                          1M                     2M                      4M

                           35             Standard        E52-IC35AY D=6.4 1M    E52-IC35AY D=6.4 2M     E52-IC35AY D=6.4 4M

                                          Heat resistive  E52-IC35AY D=6.4 NETU  E52-IC35AY D=6.4 NETU   E52-IC35AY D=6.4 NETU

                                                          1M                     2M                      4M

                           50             Standard        E52-IC50AY D=6.4 1M    E52-IC50AY D=6.4 2M     E52-IC50AY D=6.4 4M

                                          Heat resistive  E52-IC50AY D=6.4 NETU  E52-IC50AY D=6.4 NETU   E52-IC50AY D=6.4 NETU

                                                          1M                     2M                      4M

               8 dia.      20             Standard        E52-IC20AY D=8 1M      E52-IC20AY D=8 2M       E52-IC20AY D=8 4M

                                          Heat resistive  E52-IC20AY D=8 NETU    E52-IC20AY D=8 NETU     E52-IC20AY D=8 NETU

                                                          1M                     2M                      4M

                           35             Standard        E52-IC35AY D=8 1M      E52-IC35AY D=8 2M       E52-IC35AY D=8 4M

                                          Heat resistive  E52-IC35AY D=8 NETU    E52-IC35AY D=8 NETU     E52-IC35AY D=8 NETU

                                                          1M                     2M                      4M

                           50             Standard        E52-IC50AY D=8 1M      E52-IC50AY D=8 2M       E52-IC50AY D=8 4M

                                          Heat resistive  E52-IC50AY D=8 NETU    E52-IC50AY D=8 NETU     E52-IC50AY D=8 NETU

                                                          1M                     2M                      4M

                                                                                                                                12
                                                                                                                                                                     E52

Exposed-terminal Models

E52-CA@B-N

E52-IC@B-N

Dimensions                                                                                       Permissible Temperature in Dry Air

Dimensions are given in millimeters, except for the length (L),                which             D                                Element wire

is provided in centimeters.                                                                                               K (CA)                J (IC)

                        38.5  Terminal box             Sheath                                                     ASTM316L                      ASTM316L

                                  Socket (SUS304)      (ASTM316L)                                3.2 dia.  750°C                     650°C

               +                                                                                 4.8 dia.  800°C                     750°C

           44                                                               D

               −                                                                                 6.4 dia.  800°C                     750°C

                                       Caulking

                              15                 (See note)                                      8.0 dia.  900°C                     750°C

    16     Two, M3                               L-40

                                                                                                 Terminal box: The permissible temperature is 0°C to 100°C.

Note: The length L is in centimeters, but “40” is 40 millimeters.

           Therefore, for the E52-CA50B-N: L = 50 (cm), the sheath length                  L  −  40 = 500 − 40 = 460 mm.

Model Information

Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.

Element type            Terminal type       Protective                                           Protective tubing diameter D (mm)

                                            tubing length           3.2 dia.                     4.8 dia.                 6.4 dia.                           8 dia.

                                                 L (cm)

                                                                                                                 Model

K (CA)                  Exposed-ter-   20                      E52-CA20B-N D=3.2              E52-CA20B-N D=4.8   E52-CA20B-N D=6.4  ---

                        minal Models   35                      E52-CA35B-N D=3.2              E52-CA35B-N D=4.8   E52-CA35B-N D=6.4  E52-CA35B-N D=8

                                       50                      E52-CA50B-N D=3.2              E52-CA50B-N D=4.8   E52-CA50B-N D=6.4  E52-CA50B-N D=8

                                       75                      ---                            E52-CA75B-N D=4.8   E52-CA75B-N D=6.4  E52-CA75B-N D=8

J (IC)                  Exposed-ter-   20                      E52-IC20B-N D=3.2              E52-IC20B-N D=4.8   E52-IC20B-N D=6.4  ---

                        minal Models   35                      E52-IC35B-N D=3.2              E52-IC35B-N D=4.8   E52-IC35B-N D=6.4  E52-IC35B-N D=8

                                       50                      E52-IC50B-N D=3.2              E52-IC50B-N D=4.8   E52-IC50B-N D=6.4  E52-IC50B-N D=8

                                       75                      ---                            E52-IC75B-N D=4.8   E52-IC75B-N D=6.4  E52-IC75B-N D=8

Enclosed-terminal Models

E52-CA@C-N

E52-IC@C-N

Dimensions

Dimensions are given in millimeters,             except for the     length  (L), which

is provided in centimeters.                                                                      Permissible Temperature in Dry Air

                    67        Socket (SUS304)    Sheath

                                                 (ASTM316L)                                      D                                Element wire

    Chain                                                                                                                 K (CA)                J (IC)

                                                                               D                                  ASTM316L                      ASTM316L

66                                                                                               3.2 dia.  750°C                     650°C

                                  Caulking

                              Terminal box                                                       4.8 dia.  800°C                     750°C

                                                 (See note)                                      6.4 dia.  800°C                     750°C

G3/8,                   40                       L-40                                            8.0 dia.  900°C                     750°C

Packing internal

diameter 6.5 dia.                                Use wiring terminals that fit M3 screws.        Terminal box: The permissible temperature is 0°C to 90°C.

                                                                                                 Note: The terminals in the cap indicate polarity (+ or −).

Note: The length L is in centimeters, but “40” is 40 millimeters.

           Therefore, for the E52-CA35C-N: L = 35 (cm), the sheath length                  L  −  40 = 350 − 40 = 310 mm.

Model Information

Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.

Element type            Terminal type       Protective                                           Protective tubing diameter D (mm)

                                            tubing length           3.2 dia.                     4.8 dia.                 6.4 dia.                           8 dia.

                                                 L (cm)

                                                                                                                 Model

K (CA)                  Enclosed-ter-  20                      E52-CA20C-N D=3.2              E52-CA20C-N D=4.8   E52-CA20C-N D=6.4  ---

                        minal Models   35                      E52-CA35C-N D=3.2              E52-CA35C-N D=4.8   E52-CA35C-N D=6.4  E52-CA35C-N D=8

                                       50                      E52-CA50C-N D=3.2              E52-CA50C-N D=4.8   E52-CA50C-N D=6.4  E52-CA50C-N D=8

                                       75                      ---                            E52-CA75C-N D=4.8   E52-CA75C-N D=6.4  E52-CA75C-N D=8

J (IC)                  Enclosed-ter-  20                      E52-IC20C-N D=3.2              E52-IC20C-N D=4.8   E52-IC20C-N D=6.4  ---

                        minal Models   35                      E52-IC35C-N D=3.2              E52-IC35C-N D=4.8   E52-IC35C-N D=6.4  E52-IC35C-N D=8

                                       50                      E52-IC50C-N D=3.2              E52-IC50C-N D=4.8   E52-IC50C-N D=6.4  E52-IC50C-N D=8

                                       75                      ---                            E52-IC75C-N D=4.8   E52-IC75C-N D=6.4  E52-IC75C-N D=8

                                                                                                                                                                          13
                                                                                                                                                         E52

■ Standard Thermocouples

Specifications                                                                     Permissible Temperature in Dry Air (See note.)

Element wire                     K (CA), J(IC), R                                             D                         Element wire

Class                            K (CA), J (IC) JIS class 2 (0.75)                                          K (CA) SUS316        J (IC) SUS316

                                 R, JIS class 2 (0.25)                             10 dia.           750°C                       450°C

Protective tubing material       K (CA)   SUS316                                   12 dia.           850°C                       500°C

                                 J (IC)   SUS316                                   15 dia.           850°C                       550°C

                                 R (See   JIS ceramic cat. 1 (PT1)                 22 dia.           900°C                       600°C

                                 note.)   JIS special ceramic (PT0)                Note: For details on the permissible temperature, refer to   Technical

Thermal contact                  Non-grounded type                                            Guide for Temperature Sensors.

Note: Specify PT1 or PT0 if the element is R.                                                 D             Element wire

                                                                                                                   R

                                                                                   15 dia.           0°C to 1,400°C

Exposed-terminal Models

E52-CA@B-N

E52-IC@B-N

Dimensions

Dimensions are given in millimeters, except for the length (L), which is provided in          centimeters.

                  49.5

                            Terminal box

                                Socket (SUS304)  SUS316 protective tubing

             +

         70                                                                D

             −

                            5

                                                   (See note)

25       Two, M4                                 L-50

Terminal box: The permissible temperature is 0°C to 100°C.

Note: The length L is in centimeters, but “50” is 50 millimeters.

        Therefore, for the E52-CA75B-N: L = 75 (cm), the protective        tubing  length  L  − 50 = 750 −  50  =  700  mm.

Permissible Temperature in Dry Air

         D                      Element wire

                  K (CA) SUS316           J (IC) SUS316

10 dia.           750°C               450°C

12 dia.           850°C               500°C

15 dia.           850°C               550°C

22 dia.           900°C               600°C

Model Information

Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.

Element type      Terminal type  Protective                                           Protective tubing diameter D (mm)

                                 tubing length                 10 dia.                     12 dia.                      15 dia.                 22 dia.

                                      L (cm)

                                                                                                      Model

K (CA)            Exposed-ter-   35                E52-CA35B-N D=10                E52-CA35B-N D=12         E52-CA35B-N D=15            ---

                  minal Models   50                E52-CA50B-N D=10                E52-CA50B-N D=12         E52-CA50B-N D=15            E52-CA50B-N D=22

                                 75                E52-CA75B-N D=10                E52-CA75B-N D=12         E52-CA75B-N D=15            E52-CA75B-N D=22

                                 100               E52-CA100B-N D=10               E52-CA100B-N D=12        E52-CA100B-N D=15           E52-CA100B-N D=22

J (IC)            Exposed-ter-   35                E52-IC35B-N D=10                E52-IC35B-N D=12         E52-IC35B-N D=15            ---

                  minal Models   50                E52-IC50B-N D=10                E52-IC50B-N D=12         E52-IC50B-N D=15            E52-IC50B-N D=22

                                 75                E52-IC75B-N D=10                E52-IC75B-N D=12         E52-IC75B-N D=15            E52-IC75B-N D=22

                                 100               E52-IC100B-N D=10               E52-IC100B-N D=12        E52-IC100B-N D=15           E52-IC100B-N D=22

                                                                                                                                                              14
                                                                                                                                                         E52

Enclosed-terminal Models

E52-CA@C-N

E52-IC@C-N

Dimensions

Dimensions are given in millimeters, except for              the  length  (L), which is provided    in  centimeters.

                   96

                                  Terminal box

Chain                                                                     SUS316 protective tubing

86                                                                                                                                      D

                                                 Socket (SUS304)

                                              40 dia.

                                              5                                            (See note)

                       53                                                            L-50

            G1/2,

            Packing internal diameter 9 dia.

Note: The length L is in centimeters, but “50” is 50 millimeters.

        Therefore, for the E52-CA50C-N: L = 50 (cm), the protective tubing length L − 50 = 500 − 50 = 450 mm.

Permissible Temperature in Dry Air

         D                     Element wire

                   K (CA) SUS316                       J (IC) SUS316

10 dia.            0 to 750°C                    0 to 450°C

12 dia.            0 to 850°C                    0 to 500°C

15 dia.            0 to 850°C                    0 to 550°C

22 dia.            0 to 900°C                    0 to 600°C

Terminal box: The permissible temperature is 0°C to 90°C.

Note: The terminals in the cap indicate polarity (+ or −).

Model Information

Custom-made models are available on request. Refer to Model Number Legend on page 8 for details

Element type       Terminal type                 Protective                                Protective tubing diameter D (mm)

                                              tubing length           10 dia.                       12 dia.           15 dia.                   22 dia.

                                                 L (cm)

                                                                                                              Model

K (CA)             Enclosed-ter-  35                              E52-CA35C-N D=10         E52-CA35C-N D=12           E52-CA35C-N D=15     ---

                   minal Models   50                              E52-CA50C-N D=10         E52-CA50C-N D=12           E52-CA50C-N D=15     E52-CA50C-N D=22

                                  75                              E52-CA75C-N D=10         E52-CA75C-N D=12           E52-CA75C-N D=15     E52-CA75C-N D=22

                                  100                             E52-CA100C-N D=10        E52-CA100C-N D=12          E52-CA100C-N D=15    E52-CA100C-N D=22

J (IC)             Enclosed-ter-  35                              E52-IC35C-N D=10         E52-IC35C-N D=12           E52-IC35C-N D=15     ---

                   minal Models   50                              E52-IC50C-N D=10         E52-IC50C-N D=12           E52-IC50C-N D=15     E52-IC50C-N D=22

                                  75                              E52-IC75C-N D=10         E52-IC75C-N D=12           E52-IC75C-N D=15     ---

                                  100                             E52-IC100C-N D=10        E52-IC100C-N D=12          E52-IC100C-N D=15    ---

                                                                                                                                                              15
                                                                                                                                                                                               E52

Enclosed-terminal Models (High-temperature Use)

E52-PR@C-N

Dimensions

Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.

                     96                                                                                                                                                    Permissible

                                                                                                                               When   L = 500                              Temperature in Dry Air

                                                 Terminal box          SUS304         Porcelain       protective tube

                                                                                                                               Swing  of protective tube: 6  mm  or  less  D        Element wire

    Chain                                                                                                                                                                                   R

86                                                    22 dia.                                                                                                    15  dia.  15 dia.  0°C to 1,400°C

                                                    Lock nut (SUS304)                                                                                                      Terminal box: The

                                             40 dia.                   Filled   with  heat resistant  cement                                                               permissible temperature

                                                 5                                                                                                                         is 0°C to 90°C.

                                                                                                              (See note)

                              53                      100                                             L-150                                                                Note: The terminals in

           G1/2,                                                                                                                                                              the cap indicate

           Packing  internal  diameter  9  dia.                                                               Use wiring terminals    that fit M4 screws.                     polarity (+ or −).

Note: The length L is in centimeters, but “150” is 150 millimeters.

           Therefore, for the E52-PR75C-N: L = 75 (cm), the protective tubing                         length  L        −  150  =  750  −  150  =  600        mm.

Model Information

Element             Terminal            Protective             Protective tubing

    type             type                   tubing             diameter D (mm)

                                           length L                    15 dia.

                                            (cm)

                                                                       Model

R (See            Enclosed-ter-         50            E52-PR50C-N D=15 PT1

note 1.)          minal Models          75            E52-PR75C-N D=15 PT1

                                        100           E52-PR100C-N D=15 PT1

R (See            Enclosed-ter-         50            E52-PR50C-N D=15 PT0

note 2.)          minal Models          75            E52-PR75C-N D=15 PT0

                                        100           E52-PR100C-N D=15 PT0

           Standard               Protective tubing                    Permissible

                                            material           temperature in dry

                                                                       air

Note 1:                       Mullite, high                    1,500°C (See note.)

JIS ceramic Cat.1             alumina, etc.

(PT1)

Note 2:                       Recrystallized                   1,700°C (See note.)

JIS special ceramic           alumina, fused

(PT0)                         alumina, etc.

Note: The permissible temperature given for the protective tubing is

           higher than 1,400°C, but the permissible temperature of the

           thermocouple element wire is only 1,400°C. Therefore, the

           protective tubing of the E52-PR@C-N can withstand high

           temperatures momentarily to the levels given in the table as

           exceptions, but the element wire will deteriorate quickly if the

           thermocouple is used regularly at temperatures that exceed the

           permissible temperature for the element wire.

                                                                                                                                                                                                    16
                                                                                                                                                                           E52

Low-cost Models

■ Low-cost Platinum Resistance Thermometers

Exposed-lead Models with Screws

Specifications                         E52-P6DY

Element type       Pt100               Dimensions

Conductor type     3-conductor system                                            Tapered pipe thread         Fluororesin-covered wire

Class              Class B                                    Argon arc welding  SUS304                      with 1.0 outer dia. each

                                                         SUS304 (t0.25)          R1/8      Silicone tubing   (PFA) 7/0.18

Protective tubing  SUS304                        4 dia.                                           Caulking                       Red (A)

material                                                                                                                         Black (B)

Sensor length      30 mm                                                                                                         Black (B)

Max. detectable    250°C                                                                          30        Y-type crimp

                                          14                                      10    6                   terminal for M3.5

temperature                                                               65                  15                M

Temperature        −50°C to 250°C      Note:     The protective tubing is of pipe construction, which must not be                            bent.

range                                     Lead wire length (m)                                    Model

Lead wire          −50°C to 150°C      1                                         E52-P6DY 1M

                                       2                                         E52-P6DY 2M

                                       4                                         E52-P6DY 4M

Exposed-lead Models with Flange

Specifications                         E52-P6FY

Element wire       Pt100               Dimensions

Conductor type     3-conductor system         Flange                                                               Fluororesin-covered wire

Class              Class B                               Three, 3.5 dia.          SUS304                           with 1.0 outer dia. each

                                                         120° SUS304 (t0.25) 4 dia.               Silicone tubing  (PFA) 7/0.18

Protective tubing  SUS304              120°                                                           Caulking                         Red (A)

material                                                                                                                               White (B)

Sensor length      30 mm                                                                          Silver                               White (B)

Max. detectable    250°C                                                                          soldering  Y-type crimp

temperature                                   20 dia.                                      1          30     terminal for M3.5

                                              30 dia.                         65                  15               M

Temperature        −50°C to 250°C      Note: The       protective tubing is of pipe               construction, which must not be bent.

range

Lead wire          −50°C to 150°C         Lead wire length (m)                                    Model

                                       1                                         E52-P6FY 1M

                                       2                                         E52-P6FY 2M

                                       4                                         E52-P6FY 4M

Exposed-lead Models

Specifications                         E52-P10AEY

Element type       Pt100               Dimensions

Conductor type     3-conductor system                                                                                                                   Y-type crimp

Class              Class B                                                                                                             Product label    terminal for M3.5

Protective tubing  SUS316                                100                                                              M

material                                                      (30)               Fluororesin-covered wire with 1.0 outer dia.                                              White (B)

                                                                                 each (PFA) 7/0.2                                                       B

Max. detectable    250°C                                                                                                                                B                  White (B)

                                                                                                                                                        A                  Red (A)

temperature                            3.2 dia.

                                                                    Caulking  Silicone                                         Shrinkable tube (black)  Marker tube

Temperature        0°C to 250°C                                               shrinkable tubing

range                                  Note: 1.      The protective tubing is of pipe construction, which must not be bent.

Lead wire          −50°C to 180°C                2.  A Compression Fitting (PT@) cannot be used for mounting.

                                          Lead       wire length    (m)                           Model

                                       1                                         E52-P10AEY 1M

                                       2                                         E52-P10AEY 2M

                                       4                                         E52-P10AEY 4M

                                                                                                                                                                                      17
                                                                                                                                                                       E52

■ Low-cost Thermocouples

Exposed-lead Models with Spring

Specifications                                 E52-CA@ASY, E52-IC@ASY

Element type          K (CA), J (IC)           Dimensions

Element dia.          0.65 mm (single wire)                                                                          Marker tube(White)

                                                                                                         Lead Wire(Red)

Class                 Class 2 (0.75)           L±3                            32                            M

Protective tubing     SUS304                   SUS304 (t0.4)                  12 dia.  150                                     80         (+)

                                                                                                                                   +

material                                                                                                                           −

Thermal contact       Non-grounded type        4.8 dia.       Sleeve                                           Lead Wire                  (−)

Temperature range     0°C to 400°C: K (CA)                    Brass-nickel             Closely wound           (White)                Y-type crimp

                                                              plating                  spring coil                                    terminal for M3.5

                      0°C to 350°C: J (IC)                                    Fully glass-wool-covered   Color code  Marker tube(White)

Lead wire             0°C to 180°C                                            compensating cable with    (K: Blue, J: Yellow)         L:  Protective     tubing  length

                                                                              four 0.65-dia. conductors

                                                                              and external dimensions                                 M:  Lead wire      length

Note: The sleeve resists temperatures ranging                                 of approx. 5.1 × 3.0

       between 0°C and 100°C.

Note: The protective tubing is of pipe construction, which must not be bent.

Protective    tubing  length  (mm)     Lead wire length (m)                            Element type:     K  (CA)                          Element type:  J       (IC)

                                                                                                                         Model

65                                  1                                         E52-CA6ASY 1M                                           E52-IC6ASY 1M

                                    2                                         E52-CA6ASY 2M                                           E52-IC6ASY 2M

                                    4                                         E52-CA6ASY 4M                                           E52-IC6ASY 4M

100                                 1                                         E52-CA10ASY 1M                                          E52-IC10ASY 1M

                                    2                                         E52-CA10ASY 2M                                          E52-IC10ASY 2M

                                    4                                         E52-CA10ASY 4M                                          E52-IC10ASY 4M

150                                 1                                         E52-CA15ASY 1M                                          E52-IC15ASY 1M

                                    2                                         E52-CA15ASY 2M                                          E52-IC15ASY 2M

                                    4                                         E52-CA15ASY 4M                                          E52-IC15ASY 4M

200                                 1                                         E52-CA20ASY 1M                                          E52-IC20ASY 1M

                                    2                                         E52-CA20ASY 2M                                          E52-IC20ASY 2M

                                    4                                         E52-CA20ASY 4M                                          E52-IC20ASY 4M

                                                                                                                                                                            18
                                                                                                                                                                             E52

Exposed-lead Models with Screw

Specifications                                       E52-CA1DY, E52-IC1DY

Element type              K (CA), J (IC)             Dimensions

Element dia.              0.65 mm (single wire)                                                            M

Class                     Class 2 (0.75)             0.65-dia.      2.8       1  10   A  C                 Color tubing          80

                                                     thermocouple                                  Brass   (K: Blue,

Protective tubing         SUS304                     element                                               J: Yellow)                Red (+)

material                                                          B 3.8 dia.

Thermal contact           Grounded type                                                                                              White (−)

                                                                                         5 dia.               Color code

Temperature range         0°C to 400°C: K (CA)             Movable ring       SUS304                          (K: Blue,          Crimp terminal for M3.5

                                                           (brass)            screw                           J: Yellow)

                          0°C to 350°C: J (IC)                                (W1/4)  Enamel-bonded

                                                                                      copper wire          Fully glass-wool-covered with external

Lead wire                 0°C to 180°C                                                                     copper shield and external dimensions of

Terminal shape            Y-type crimp terminal                                                            approx. 3.1 × 2.0

                          for M3.5

Note: 1.   The thermocouple is a single wire from    Internal Construction (E52-CA1DY)                                               Lead wire             Screw

           the tip to the terminal.                                                                                                  length (m)

       2.  Specify the type of screw (i.e., M6, M8,        0.65-dia.                                                                                 W1/4     M6       M8

           or W1/4) when ordering.                         black wire                                  Closely wound                 A (mm)          4.3   4           5.3
                                                                    Movable ring
                                                           Brass                                       enamel-bonded      coil.

       3.  The thermocouple is not of airtight                                                                                       B (mm)          11.5  11.5        15

           construction.                                                                                                             C (mm)          3.8   3.8         3.8

       4.  OMRON recommends that the tip of the

           thermocouple is touching the sensing

           object.                                   Cut after silver            M6                    Brass pipe

Installation Example                                 soldering

                                                                                      Screw      Shielded

Cut a thread into the workpiece, and screw in the                                                glass-wool lead

thermocouple while pushing in so that the tip                                                    wire

makes complete contact.

End                 Workpiece

Note: E52-CA1DY with the same shape       and multiple     element wires         are  also available (E52-CA1DY-40).

       Refer to page 26 for details.

Protective tubing length (mm)                   Lead wire  length (m)                            Element type: K          (CA)                       Element type:  J  (IC)

                                                                                                                                     Model

M6 screw                              1                                               E52-CA1DY M6 1M                                E52-IC1DY M6 1M

                                      2                                               E52-CA1DY M6 2M                                E52-IC1DY M6 2M

                                      4                                               E52-CA1DY M6 4M                                E52-IC1DY M6 4M

M8 screw                              1                                               E52-CA1DY M8 1M                                E52-IC1DY M8 1M

                                      2                                               E52-CA1DY M8 2M                                E52-IC1DY M8 2M

                                      4                                               E52-CA1DY M8 4M                                E52-IC1DY M8 4M

W1/4 screw                            1                                               E52-CA1DY W1/4 1M                              E52-IC1DY W1/4 1M

                                      2                                               E52-CA1DY W1/4 2M                              E52-IC1DY W1/4 2M

                                      4                                               E52-CA1DY W1/4 4M                              E52-IC1DY W1/4 4M

                                                                                                                                                                                  19
                                                                                                                                                        E52

Exposed-lead Models               with Flange

Specifications                    E52-CA6F-N, E52-IC6F-N

Element type     K (CA), J (IC)   Dimensions

Class            Class 2 (0.75)                                              Silver soldering      Fluororesin-covered thermocouple wire with external

Protective       SUS304                 Three, 3.5 dia.                                  Silicon   dimensions of 1.6 × 1.0 (CA) and 1.6 × 1.0 (IC)

tubing material                                                          SUS304          shrinkable tube      Peel processed

                                  120°           120°  4 dia.    SUS304            Caulking

Thermal contact  Grounded type                                                                                           Red (+)

Temperature      0°C to 350°C: K                                                                                         White (−)

                                                                                                Shrinkable

range            (CA)                                                        1           30     tube          80±10              10

                 0°C to 350°C: J        20 dia.                      65±2          15                     M

                 (IC)                   30 dia.                                              Lead wire length (M): 1, 2, or 4 m

Lead wire        0°C to 150°C

                                  Note: 1.       The thermocouple is a single wire from the tip to the terminal.

                                            2.   The protective tubing is of pipe construction, which must not be bent.

                                     Lead wire                 Element type: K (CA)                   Element type: J (IC)

                                     length (m)                                                 Model

                                  1                      E52-CA6F-N 1M                             E52-IC6F-N 1M

                                  2                      E52-CA6F-N 2M                             E52-IC6F-N 2M

                                  4                      E52-CA6F-N 4M                             E52-IC6F-N 4M

Exposed-lead Models               with Screws

Specifications                    E52-CA6D-N, E52-IC6D-N

Element type     K (CA), J (IC)   Dimensions

Class            Class 2 (0.75)                          Tapered  pipe                       Fluororesin-covered thermocouple wire   with external

Protective       SUS304                                  thread          Silicon             dimensions of 1.6 × 1.0 (CA) and 1.6    × 1.0 (IC)

tubing material                   14                     SUS304          shrinkable  tube          Peel processed

                                        4 dia.           R 1/8           Caulking

Thermal contact  Grounded type                                                                                     Red (+)

Temperature      0°C to 350°C: K                                                                                   White (−)

                                                                                       Shrinkable

range            (CA)                                             6          30        tube            80±10         10

                 0°C to 350°C: J                         65±2            15                     M

                 (IC)                                                                           Lead wire length (M): 1, 2, or 4 m

Lead wire        0°C to 150°C     Note: 1.       The thermocouple is a single wire from the tip to the terminal.

                                            2.   The protective tubing is of pipe construction, which must not be bent.

                                     Lead wire                 Element type: K (CA)                   Element type: J (IC)

                                     length (m)                                                 Model

                                  1                      E52-CA6D-N 1M                             E52-IC6D-N 1M

                                  2                      E52-CA6D-N 2M                             E52-IC6D-N 2M

                                  4                      E52-CA6D-N 4M                             E52-IC6D-N 4M

Exposed-lead Models

Specifications                    E52-CA10AE-N, E52-IC10AE-N

Element type     K (CA), J (IC)   Dimensions

Class            Class 2 (0.75)                                   Fluororesin-covered thermocouple wire with external

Protective       SUS304                                           dimensions of 1.6 × 1.0 (CA) and 1.6 × 1.0 (IC)

tubing material                                  Protective tubing                                 Peel processed

                                  3.2 dia.

Thermal contact  Non-grounded                                                                                 Red (+)

                 type                                                                                         White (−)

Temperature      0°C to 350°C: K            SUS304             Caulking            Shrinkable          10

                                                                                   tube               80

range            (CA)                                    100                                 M

                 0°C to 200°C: J

                 (IC)             Note:     1.   The thermocouple is a single wire from the tip to the terminal.

Lead wire        0°C to 180°C               2.   Lead wire length M: 1, 2, or 4 m

                                            3.   The protective tubing is of pipe construction, which must not be bent.

                                            4.   The thermocouple cannot be mounted using a PT@ Compression Fitting.

                                     Lead wire                 Element type: K (CA)                   Element type: J (IC)

                                     length (m)                                                 Model

                                  1                      E52-CA10AE-N 1M                           E52-IC10AE-N 1M

                                  2                      E52-CA10AE-N 2M                           E52-IC10AE-N 2M

                                  4                      E52-CA10AE-N 4M                           E52-IC10AE-N 4M

                                                                                                                                                             20
                                                                                                                                                                                              E52

Exclusive Models

■ Thermocouples

Thermocouples for Molding Machines

Specifications                          E52-CA2GVY, E52-IC2GVY

Element type     K (CA), J (IC)         Dimensions

Element          1.0 mm (single                                   Bayonet                 (MBTTDPWFSFETUBJOMFTTTUFFMTIJFMEFE

diameter         wire)                                                                    UIFSNPDPVQMFXJSF             :UZQFDSJNQ                      Adapter (provided)

Class            Class 2 (0.75)                         12.5      dia.            4QSJOH                                UFSNJOBMGPS.                           (See note.)

                                                        14 dia.         15 dia.       4QSJOHSFUBJOFS  .BSLFSUVCF                                     5 dia. 3ʗ

Protective       SUS304                      464                     6.8 dia.          4.1 dia.

tubing material                                                                                                 +        Red (+)                                         8 dia.      12 dia.

                                                                                                                −        White (−)

Thermal contact  Grounded type          4.8  dia.       25±2      15              22                   Shrinkable tube                                               10

Temperature      0°C to 350°C                                           100±10                                 85±10                                             10  15

range                                                                                 .                                                                Note: The Adapter is included

Lead wire        0°C to 180°C                                     Lead wire length (M): 1 or 2 m                                                                    with the Thermocouple.

                                                                                                                                                                    If it is lost or damaged,

                                                                                                                                                                    you can order a

                                                                                                                                                                    replacement with the

                                                                                                                                                                    following model number.

                                                                                                                                                                    Adapter: Y92F-S1

                                           Lead wire                    Element type: K (CA)                          Element type:        J   (IC)

                                           length (m)                                                  Model

                                        1                         E52-CA2GVY 1M                                E52-IC2GVY 1M

                                        2                         E52-CA2GVY 2M                                E52-IC2GVY 2M

Thermocouples with Crimp Terminals

Specifications                             E52-CA1GTY, E52-IC1GTY

Element type     K (CA), J (IC)            Dimensions

Element          0.65 mm (single             M4, round crimp terminal                 Glass-wool-braided shield with maximum

diameter         wire)                            8           Silicone tubing         external dimensions of 2.6 × 4.0

Class            Class 2 (0.75)                                                                                                      White/red stripe (+)

Thermal contact  Grounded type                                                            Color code                                 White stripe (−)

Temperature      0°C to 300°C                4.3 dia.         15        6 dia. max.       (K: Blue, J: Yellow)           80

range                                                                                     M                                       Y-type crimp

                                                                        Lead wire length (M): 1 or 2 m                            terminal for M3.5

Lead wire        0°C to 150°C

Terminal shape   Y-type crimp                   Lead wire               Element type: K (CA)                            Element type: J (IC)

                 terminal for M3.5              length (m)                                                     Model

Note: The E52-CA1GTY is also                 1                          E52-CA1GTY 1M                                 E52-IC1GTY 1M

       available with double elements.       2                          E52-CA1GTY 2M                                 E52-IC1GTY 2M

       Refer to page 26 for details.

■ Platinum Resistance Thermometers

Platinum Resistance Thermometers for Surface Temperature Measurement

Specifications                             E52-P2GSY

Element type     Pt100                     Dimensions

Class            Class B                                                                                       Silicone-covered 3-conductor cable

Protective       SUS304                                                 Brass-nickel-plated bracket            with thirty 0.08-dia. conductors (0.15-mm thick)

tubing material  With brass-nickel-                                     Four, 3.2 dia.                         and approx. 3.9 dia.             Product label        Marker tube

                 plated bracket                      3

                                                                                                       6-dia.  Caulking                                                                 Red (A)

Conductor type   3-conductor                                                                                                                                             A

                                                              5   20±1            5                                                                                      B              White (B)

                 system                                                                                                                                                  B

                                             1.5        4.50            14±0.6                                                                                                          White (B)

Temperature      −50°C to 250°C                                                           20±0.5                      Silicon shrinkable tube                30

range                                                6                                                                                         Name plate A

                 −50°C to 150°C                                                           28±1         30                              M                                 80

Lead wire                                                                                                                                       Lead wire length (M): 1 or        2  m

                                             Lead wire length (m)                                      Model

                                             1                                            E52-P2GSY 1M

                                             2                                            E52-P2GSY 2M

                                                                                                                                                                                                   21
                                                                                                                                                                                   E52

Platinum Resistance Thermometers for Room                                                      Temperature Measurement

Specifications                                  E52-P10GRY

Element type        Pt100                       Dimensions

Class               Class B                                                              70±1  dia.          Two,      8  dia.

Protective tubing   SUS304                                        Aluminum alloy AC3A

material

Conductor type      3-conductor system                            42±1 dia.

Temperature range   −50°C to 60°C                                                                                                     6.1 dia.     27 dia.

Lead wire           −20°C to 60°C

                                                                                               69.5±1

                                                                                                                                6.1-outer-dia.

                                                22.2  dia.  BS (Ni plated)                                                      vinyl-covered 3-conductor       Y-type crimp

                                                            8.0 dia. SUS304                                                     cable (twenty 0.18-dia.         terminal for M3.5

                                                            Enclosed resistance                                                 conductors, 0.5 mm thick)

                                                            thermometer                                                   56          (30)

                                                                                                                                                            A          Red (A)

                                                                                                                                                            B          White (B)

                                                                                                                                                            B          Black (B)

                                                      4.8   dia.                                                                Shrinkable         Marker tube

                                                                  95                                                            tube               85±10

                                                                  100                              97                                 2,000

                                                Lead wire length (m)                               Model

                                                2                                E52-P10GRY 2M

Waterproof Platinum Resistance Thermometers

Specifications                                     E52-P10GPY

Element wire        Pt100                          Dimensions

Class               Class B                                                                            6.1-outer-dia. vinyl-covered                Y-type crimp

                                                                                                       3-conductor cable (twelve 0.18-dia.         terminal for M3.5

Protective tubing   SUS304                                                                             conductors, 0.5 mm thick)

material                                              SUS304 protective      tubing      20 dia.                                     Marker tube

Conductor type      3-conductor system             7 dia.                                                    6.1 dia.     Name plate                        Red (A)

                                                                                                                                                A           White (B)

                                                                                                                                                B

Temperature range   0°C to 70°C (underwater)                                                                                                    B           White (B)

                    −20°C to 70°C (in the air)                                                               Shrinkable         (30)

Lead wire           −25°C to 60°C                                      98            12                      tube                     85±10

Resistive pressure  10 kg/cm2 max.                                     100                     62      5                        M

                                                                                                                          Lead wire length (M): 2 or 4 m

                                                   Note: The lead wires are vinyl-covered, and cannot be used underwater.

                                                            Use the E52-P5AY-40 if waterproof lead wires are required for use underwater.

                                                            Refer to page 23 for details.

                                                                                                          Lead wire length (m)                                  Model

                                                                                                          2                                        E52-P10GPY 2M

                                                                                                          4                                        E52-P10GPY 4M

                                                                                                                                                                                        22
                                                                                                                                                                     E52

Corrosion-resistant Models with Fluororesin-covered

Protective Tubing

■ Thermocouples

Exposed-lead       Models

Specifications                             E52-CA20AY-1

Element type       K (CA)                  Dimensions

Class              Class 2 (0.75)                                                                                  Fixed with adhesive tape and

                                                                                 Product label                     silicone heat-shrinking tube

Protective tubing  ASTM316L with                        Y-type crimp                    Compensating                  Sleeve       Sheath

material           Fluororesin-covered                  terminal for M3.5               conductor

                   (FEP) tube                                                                                      d                                           D

                                                   Red (+)       +

Thermal contact    Non-grounded type               White (−)     −

                                                                                 Filled with epoxy resin           Caulking        FEP-covered tubing

Temperature range  0°C to 180°C                                     90±10               2,000                                                200

Lead wire          Vinyl-covered: −20°C

                   to 70°C                                    Model                     Protective                 Sleeve diameter           Covering          Lead wire

                                                                                        tubing                             (mm)              thickness         length (m)

                                                                                        diameter                   Sleeve length                  (mm)

                                                                                                                           (mm)

                                           E52-CA20AY-1 D=4.6 2M                    D = 4.6                d=8                               0.7            2

                                           E52-CA20AY-1 D=6 2M                      D = 6.0                        l = 55                    0.6

                                           E52-CA20AY-1 D=8 2M                      D = 8.0                d = 11                            0.8

                                                                                                           l = 55

■ Platinum Measurement

Exposed-lead       Models

Specifications                             E52-P20AY-1

Element type       Pt100                   Dimensions

Class              Class B                                                                                         Fixed with adhesive tape and

Protective tubing  SUS316 with                     Y-type crimp                  Filled with epoxy resin           silicone heat-shrinking tube

                                                   terminal for M3.5

material           Fluororesin-covered                        Marker tube  Lead wires           Sleeve                     Sheath

                   (FEP) tube                      Red                                                 (9.5 dia.)                       D

                                                              A

Conductor type     3-conductor system      White              B

                                                              B

Temperature range  −80°C to 180°C          White                           Shrinkable tube         d       FEP-covered tubing

Lead wire          Vinyl-covered: −20°C                       85±10              2,000             35                 205

                   to 70°C                                    Model                     Protective                    Sleeve        Coating                Lead wire

                                                                                        tubing                     diameter        thickness               length (m)

                                                                                        diameter                      (mm)              (mm)

                                           E52-P20AY-1 D=4.6 2M                  D = 4.6                           d=8             0.7                  2

                                           E52-P20AY-1 D=6 2M                    D = 6.0                           d=8             0.6

                                           E52-P20AY-1 D=8 2M                    D = 8.0                           d=8             0.8

FEP-molded Models (Completely Waterproof)

Specifications                             E52-P5AY-40

Element type       Pt100                   Dimensions                                                                                            Y-type crimp terminal for M3.5

                                                                                                                                                        Marker tube

Class              Class B                 Element FEP mold                                                                        PFA-covered wire 0.18/7

Protective tubing  Fluororesin (FEP) tube                     Fused (completely  waterproof)                                  Product label

material           (element / fluororesin  6 dia.                                               3.5 dia.                                                             Red (A)

                                                                                                                                                            A        White (B)

                   mold (FEP))                                                                                                                              B

                                                                                                                                                            B

Conductor type     3-conductor system                   65                                                                                                           White (B)

Temperature range  −50°C to 180°C                                                                                                            30±5          80

                                                                                                                                                        90±10

Lead wire          Fluororesin (FEP)                                                                    M

                   cover (with outer                          Model              Lead wire length                     (m)

                   cover): −50°C to 180°C

                                           E52-P5AY-40 2M                        2

                                           E52-P5AY-40 4M                        4

                                           E52-P5AY-40 6M                        6

                                           E52-P5AY-40 8M                        8

                                                                                                                                                                                 23
                                                                                                                                               E52

Pressure-resistant Explosion-proof (IICT6)                                                                  Models

■ Thermocouples

Enclosed-terminal Models

E52-CA@@C-N-6

                                               L                                    131.5

Dimensions                          L2                          L1

                                                       Socket (SUS304)      10

                    6.4 dia.                           15 dia.

                                                                                                                              113              113

                    Sheath

                    (ASTM316L)                 SUS304

Specifications                                                      O-ring

Element type                        K (CA)

Class                               Class 2 (0.75)

                                    Class 3 (Level 1.5) at -40°C                                                                               64.6

                                    and under

Protective tubing material          L2 section: ASTM316L

                                    L1 section: SUS304

Explosion-  Construction            Pressure-resistant                          70                                      G1/2

proof                               explosion-proof structure

specifica-  Explosion-protected     IICT6

tions       class and ignitability

            Explosion-proof         −20°C to 85°C                                   Model                   Protective        Protective  L2

            temperature range                                                                               tubing length     tubing      (mm)

            Lead wire wiring        Pressure-resistant                                                          L (cm)        diameter

            method                  packing cable ground type               E52-CA20C-N-6 D=6.4     L2=150  20                D = 6.4     150

            Conduit thread          G1/2                                    E52-CA35C-N-6 D=6.4     L2=300  35                D = 6.4     300

            Installation method     Conforms to Technical                   E52-CA50C-N-6 D=6.4     L2=450  50                D = 6.4     450

                                    Recommendations of the                  E52-CA75C-N-6 D=6.4     L2=700  75                D = 6.4     700

                                    Research Institute of

                                    Industrial Safety (Japan)

■ Platinum Resistance Thermometers for Surface Temperature Measurement

Enclosed-terminal Models

E52-P@@C-N-6

                                               L                                    131.5

Dimensions                          L2                          L1

                                                                            10

                                                       Socket (SUS304)

                    6.4 dia.                           15 dia.

                                                                                                                                               113

                    Sheath

                    (ASTM316L)               SUS304                 O-ring

Specifications

Element type                        Pt100

Class                               Class B

Protective tubing material          L2 section: ASTM316L

                                    L1 section: SUS304                                                                                         64.6

Explosion-  Construction            Pressure-resistant

proof                               explosion-proof structure

specifica-  Explosion-protected     IICT6                                       70                              G1/2

tions       class and ignitability

            Explosion-proof         −20°C to 85°C

            temperature range                                                       Model                   Protective        Protective  L2

            Lead wire wiring        Pressure-resistant                                                      tubing length     tubing      (mm)

            method                  packing cable ground type                                                   L (cm)        diameter

            Conduit thread          G1/2                                        E52-P20C-N-6 D=6.4  L2=150  20                D = 6.4     150

            Installation method     Conforms to Technical                       E52-P35C-N-6 D=6.4  L2=300  35                D = 6.4     300

                                    Recommendations of the                      E52-P50C-N-6 D=6.4  L2=450  50                D = 6.4     450

                                    Research Institute of                       E52-P75C-N-6 D=6.4  L2=700  75                D = 6.4     700

                                    Industrial Safety (Japan)

                                                                                                                                                     24
                                                                                                                                                                     E52

Double-element Models

■ Thermocouple

Exposed-lead Models

Specifications                           E52-CA20AY-7

Element type       K (CA)                Dimensions

Class              Class 2 (0.75)        Y-type crimp

Protective tubing  ASTM316L              terminal for M3.5                 Product label      Compensating

material           (with sheath)                       Marker tube                            conductor                               Sleeve     Sheath

                                         Red (+)                                                                                                 (ASTM316L)

Thermal contact    Non-grounded type                          +                                                                d

                                         White (−)            −

Temperature        0°C to permissible    Red (+)                                                                                                                     D

range              temperature limit                          +

                                         White (−)            −

Lead wire          Vinyl-covered: −20°C

                   to 70°C                                    80              30

                                                            90±10                                2,000                            55                     200

                                         Permissible Temperature in Dry Air

                                                  D                     Element wire

                                                                              K (CA)

                                                                           ASTM316L

                                         3.2 dia.             750°C

                                         4.8 dia.             800°C

                                         6.4 dia.             800°C

                                         8.0 dia.             900°C

                                                       Model                  Protective                 Sleeve  Permissible                  Lead wire

                                                                                  tubing         diameter        Temperature                  length (m)

                                                                              diameter                   (mm)                  (°C)

                                         E52-CA20AY-7 D=3.2 2M                D = 3.2            d = 11          750                          2

                                         E52-CA20AY-7 D=4.8 2M                D = 4.8            d = 11          800                          2

                                         E52-CA20AY-7 D=6.4 2M                D = 6.4            d = 11          800                          2

                                         E52-CA20AY-7 D=8.0 2M                D = 8.0            d = 11          900                          2

■ Platinum Resistance                    Thermometers

Exposed-lead Models

Specifications                           E52-P20AY-7

Element type       Pt100                 Dimensions

Class              Class B                             Y-type crimp

Protective tubing  ASTM316L                            terminal for M3.5      Wire marks (1, 2)

material           (with sheath)         Red (A)                 Marker tube  Indicated by pair             Lead wire with        Sleeve (SUS304)        Sheath

                                                                                          Product label     all-vinyl coating                            (ASTM316L)

Conductor type     3-conductor system    White (B)               A                                                                    11 dia.    Caulking

Temperature        −200°C to 450°C                               B            1                                  6.5 dia.

                                         White (B)            B

range                                                         A                                                                                                         D

                                         Red (A)                              2

Lead wire          Vinyl-covered: −20°C                          B

                   to 70°C               White (B)               B                                                             Filled with epoxy resin

                                         White (B)

                                                                                                 Silicon shrinkable tube

                                                                    80                    30

                                                                    90±10                                M                            55                   200±6

                                                       Model                          Protective                 Lead wire

                                                                                  tubing diameter                length (m)

                                         E52-P20AY-7 D=4.8 2M                     D = 4.8                   2

                                         E52-P20AY-7 D=6.4 2M                     D = 6.4                   2

                                                                                                                                                                           25
                                                                                                                                                                              E52

Enclosed-terminal Models

Specifications                                               E52-P20C-N-7

Element type       Pt100                                     Dimensions

Class              Class B                                                         96                                                            Terminal  for  terminal  connection

                                                                                                                                                 Size: M4

Protective tubing  ASTM316L

material           (with sheath)                                                                        Terminal box

Conductor type     3-conductor system                              82 dia.                                                       Sheath (ASTM316L)

                                                                                                               Socket (SUS304)

Temperature range  −200°C to 450°C

                                                             86                                                                                                            D

                                                                                                               Caulking

                                                                                                        15

                                                                                                                                 (See note)

                                                                                           53                                    L-50

                                                                            Model                   Protective tubing            Protective

                                                                                                     length L (cm)              tubing diameter

                                                             E52-P20C-N-7 D=4.8                     20                          D = 4.8

                                                             E52-P20C-N-7 D=6.4                     20                          D = 6.4

Note: The length L is in centimeters, but “50” is 50 millimeters.

       Therefore, for the E52-P20C-N-7: L = 20 (cm), the sheath length L − 50 = 200 − 50 = 150 mm.

Silicone-covered Lead Wires Models

■ Thermocouples

Exposed-lead Models with Screws

Specifications                                                                     E52-CA1DY-40

Element type                     K (CA)                                            Dimensions

Class                            Class 2 (0.75)                                                                                  M

Screw material                   SUS304                                                        2.8      1  10  4.2  13       80        Silicone      80

                                                                                                                                       covering                     Red (+)

Thermal contact                  Grounded type                                         11

Temperature range                0°C to 300°C                                                                                                                       White (−)

Lead wire                        Silicone-covered (0.1/30): 0°C    to                  3.8 dia.                8 dia. Caulking   SUS304

                                                                                                     Thermo-                     spring with         Silicone   Y-type crimp

                                 150°C                                                               couple                      6.5 outer dia.      covering   terminal for 3.5

                                                                                   Movable ring      element   SUS304 screw      and 5.2         Silicone

Terminal shape                   Y-type crimp terminal for M3.5                                      wire                        inside dia.     shrinkable tubing

Note: Refer to the installation  example for the E52-CA1DY.

                                                                                                    Model                        Screw pitch                    Lead wire

                                                                                                                                                                length (m)

                                                                                   E52-CA1DY-40 M6 1M                        M6                      1

                                                                                   E52-CA1DY-40 M6 2M                        M6                      2

                                                                                   E52-CA1DY-40 M6 4M                        M6                      4

Thermocouples                    with Crimp Terminals

Specifications                                                                     E52-CA1GTY-14

Element type                     K (CA)                                            Dimensions

Class                            Class 2 (0.75)                                    M4, round,        Silicone-covered

                                                                                   crimp terminal    compensating cable with

Thermal contact                  Grounded type                                                       twenty 0.18-dia.            Color tubing

                                                                                                     conductors and external     Blue CA (K)

Temperature range                0°C to 200°C                                      8                 dimensions of 5.5 dia.                                     Red (+)

Lead wire                        Silicone-covered : 0°C to 150°C

Terminal shape                   Y-type crimp terminal for M3.5                                                                                                 White (−)

                                                                                   4.3 dia.      15                              30              80

                                                                                                                             M                                  Y-type crimp

                                                                                                                                                                terminal for M3.5

                                                                                   Lead wire length (M): 1 or 2 m

                                                                                                    Model                    Lead wire length        (m)

                                                                                   E52-CA1GTY-14 1M                          1

                                                                                   E52-CA1GTY-14 2M                          2

                                                                                                                                                                                      26
                                                                                                                                     E52

Thermistors

Element Interchangeable Thermistor for E5CS                                   and E5C2

Temperature         Ranges

Temperature         Color code      Nominal resistance            Thermistor                        Lead wire

       range                                                      constant

−50°C to 50°C       Blue            6 kΩ (0°C)                  3390K         A pair of 0.12 dia. 7 Fluororesin-insulated stranded   wires with

0°C to 100°C        Black           6 kΩ (0°C)                  3390K         0.86 outer dia. each

50°C to 150°C       Red             30 kΩ (0°C)                 3450K

100°C to 200°C      Yellow          0.55 kΩ (200°C)             4300K

150°C to 300°C      Green           4 kΩ (200°C)                5133K         Flat glass-wool-shielded lead cable with 0.12 dia. 10  conductors

                                                                              and external dimensions of 2.5 × 1.55

Specifications

       Item                               E52-THE@@

Coupling method             Element interchangeable thermistor

Class                       JIS class 1

Protective tubing material  SUS304

Time constant               8 to 15 s in still water

Dissipation factor          2.4 to 2.8 mW/°C in still air

Lead wire heat resistive    180°C

temperature

Error

Detectable temperature                          Error

−50°C to 100°C              ±1°C max.

100°C to 350°C              ±1% max. of detectable temperature

Permissible Temperature

Detectable temperature                   Operating temperature

−50°C to 50°C                      100°C

0°C to 100°C                       150°C

50°C to 150°C                      200°C

100°C to 200°C                     250°C

150°C to 300°C                     350°C

Note: Models with non-standard lead wire length and protective

       tubing length are available on request.

This Thermistor is a dedicated Thermistor for the E5C2 and E5CS.

                                                                                                                                                 27
                                                                                                                                                           E52

Exposed-lead Models

E52-THE5A

Dimensions

                                                Lead wires                                                  Temperature     range  Model

                 SUS304 t0.25    Caulking       (See note.)      Color code                                 −50°C to 50°C          E52-THE5A −50-50°C 1M

4 dia.                                                                                                      0°C to 100°C           E52-THE5A 0-100°C 1M

                                                                                                            50°C to 150°C          E52-THE5A 50-150°C 1M

                                                             15     50   10                                 100°C to 200°C         E52-THE5A 100-200°C 1M

                 50                                   1,030                                                 150°C to 300°C         E52-THE5A 150-300°C 1M

Note: The lead wires have no polarity

Exposed-lead Models with Screws

E52-THE6D

                                                                                                            Temperature     range  Model

Dimensions                                                                                                  −50°C to 50°C          E52-THE6D −50-50°C 1M

                                                Tapered pipe  thread                                        0°C to 100°C           E52-THE6D 0-100°C 1M

                                                SUS304            Lead wires                                50°C to 150°C          E52-THE6D 50-150°C 1M

                         SUS304  t0.25          R1/8              (See note.)           Color code

                                                                                                            100°C to 200°C         E52-THE6D 100-200°C 1M

                 4 dia.                                                                                     150°C to 300°C         E52-THE6D 150-300°C 1M

                         Argon arc welding      10  6                               15     50  10

14

                                 65                    15                    1,000

Note: The lead wires have no polarity

Exposed-lead Models with Flange

E52-THE6F

                                                                                                            Temperature     range  Model

Dimensions                                                                                                  −50°C to 50°C          E52-THE6F −50-50°C 1M

        Three, 3.5 dia.                         SUS304        Silver                                        0°C to 100°C           E52-THE6F 0-100°C 1M

                                                              soldering      Lead wires                     50°C to 150°C          E52-THE6F 50-150°C 1M

120°             120°            SUS304  t0.25                               (See note.)       Color  code

                                                                                                            100°C to 200°C         E52-THE6F 100-200°C 1M

                         4 dia.                                                                             150°C to 300°C         E52-THE6F 150-300°C 1M

                                                                 1                         15  50     10

        20 dia.                             65                15                    1,000

        30 dia.

Note: The lead wires have no polarity

Note: 1.    The Thermistor lead cable can be extended with a standard lead wire for extension. If waterproof performance is required, be sure that

            the lead cable joint is of waterproof construction as well.

        2.  Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the

            temperature range.

                                                                                                                                                                28
                                                                                                                                                                      E52

Accessories

Compression Fittings

Model Information

     Model            Screw of part                Applicable                                            Dimension

                                 a            protective tubing                       b            c                    d                        Flat diameter

                                                   diameter

                                                                                                                                          Part c                  Part b

PT 1/8 D=1.0                     R 1/8                1.0 dia.                        5            13                   10                   14                   14

PT 1/8 D=1.6                                          1.6 dia.

PT 1/8 D=3.2                                          3.2 dia.

PT 1/8 D=4.8                                          4.8 dia.

PT 1/4 D=3.2                     R 1/4                3.2 dia.                        5            15                   12                   17                   14

PT 1/4 D=4.8                                          4.8 dia.

PT 1/4 D=6.4                                          6.4 dia.

PT 3/8 D=8                       R 3/8                8 dia.                          5            19                   15                   21                   17

PT 1/2 D=10                      R 1/2                10 dia.                         8            23.5                 19.5                 26                   21

M 12 D=4.8                       M 12                 4.8 dia.                        5            15                   12                   17                   14

Note: The Compression Fitting is not of airtight construction. Do not                    use  the  Compression Fitting  for applications  in which the exposure of    the

     sensing object will cause problems.

The compression fitting is a screw that adjusts and secures the                                                                  a

insertion length of Temperature Sensors with the above protective                                                       D                 Protective tubing dia.

tubing diameters.

The material of the Compression Fitting is SUS304 with internal                                          Sensor side                              Head side

fixing beads made of brass.

                                                                                                                              d     c     b

                                        Tighten using the retaining screw to

                                        secure to the protective tubing.

                      Main body            Lock bead      Retaining screw

        Material      SUS304               Brass          SUS304

Source: JIS B 0203 (Unit: mm)

Nomi-       T.P.I.    Outer             Effec-     Root         Stan-         Mini-

nal     (No. of       diame-            tive       diame-         dard        mum

thread  threads       ter: d            diame-     ter: d1      diame-        effec-

size        /inch)                      ter: d2                   ter         tive

                                                                posi-         screw

                                                                tion a        length:

                                                                (from              f

                                                                  pipe

                                                                  end)

PT 1/8  28            9.728         9.147          8.566        3.97          2.5

                                                                ±0.91

PT 1/4  19            13.157        12.301         11.445       6.01          3.7

                                                                ±1.34

PT 3/8  19            16.662        15.806         14.950       6.35          3.7

                                                                ±1.34

PT 1/2  14            20.955        19.793         18.631       8.16          5.0

                                                                ±1.81

                      a                 f

                                        Tapered thread

                   d  d2 d1         Standard dia.

                                                                                                                                                                           29
                                                                                                                           E52

Loose Flanges

Model Information                                                    MF-1                          MF-2

Applicable protective  Model                                         120°                                120°

tubing diameter                                                                     Three, 5 dia.                          Three, 6.5 dia.

3.2 dia.               MF-1 D=3.2

4.8 dia.               MF-1 D=4.8

6.4 dia.               MF-1 D=6.4                                          36

8 dia.                 MF-1 D=8                                                                          54 dia.

                                                                           21 dia.

10 dia.                MF-2 D=10                                           D dia.   M4                   31 dia.

12 dia.                MF-2 D=12                                                                               D dia.  M6

15 dia.                MF-2 D=15                                                        5  14

22 dia.                MF-2 D=22                                                                                                24

                                                                           23 dia.                                         6.6

Note: 1.    Use the Loose Flange in atmospheric pressure. The Loose        45 dia.                       35 dia.

            Flange is not of airtight construction.                                                      70 dia.

        2.  Use the Loose Flange at 400°C maximum.

        3.  Do not apply the Loose Flange to protective tubing

            diameters other than the applicable ones.

Material: Aluminum

                                                                                                                                            30
                                                                                                                                                    E52

Compensating Conductors

The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected

to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between

−20°C and 70°C and two types of heat-resistive models for a temperature range between 0°C and 150°C are available.

Be sure to use the compensating conductor for the extension of the length of the thermocouple.

Model Information

   Thermocouple        Heat                             Exterior                                                Model

                       resistance                                         (Length)          1m              2m           4m                   8m

R                   Standard        Fully vinyl-covered (waterproof)                WPRG-N 1M       WPRG-N 2M         WPRG-N 4M           WPRG-N 8M

                    Heat resistive  Fully glass-wool-covered                        WPRH-N 1M       WPRH-N 2M         WPRH-N 4M           WPRH-N 8M

                                    Fully glass-wool-covered with external shield   WPRH6-N 1M      WPRH6-N 2M        WPRH6-N 4M          WPRH6-N 8M

                                    of stainless steel

K (CA)              Standard        Fully vinyl-covered (waterproof)                WCAG-N 1M       WCAG-N 2M         WCAG-N 4M           WCAG-N 8M

                    Heat resistive  Fully glass-wool-covered                        WCAH-N 1M       WCAH-N 2M         WCAH-N 4M           WCAH-N 8M

                                    Fully glass-wool-covered with external shield   WCAH6-N 1M      WCAH6-N 2M        WCAH6-N 4M          WCAH6-N 8M

                                    of stainless steel

                                    Silicone-covered (See note 2.)                  WCAG-40 1M      WCAG-40 2M        WCAG-40 4M          WCAG-40 8M

J (IC)              Standard        Vinyl covered (waterproof)                      WICG-N 1M       WICG-N 2M         WICG-N 4M           WICG-N 8M

                    Heat resistive  Fully glass-wool-covered                        WICH-N 1M       WICH-N 2M         WICH-N 4M           WICH-N 8M

                                    Fully glass-wool-covered with external shield   WICH6-N 1M      WICH6-N 2M        WICH6-N 4M          WICH6-N 8M

                                    of stainless steel

Note: 1.    Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above

            100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details.

        2.  It has the same waterproof characteristics as the standard model (fully vinyl-covered) and can be used at high temperatures.

Specifications (JIS C1610-1995)

   Model    Type of           Use        Code                         Exterior                  Number of   Operating            Error  (°C)  Exterior

            thermo-                      (See note.)                                            wires/wire  temperature                       color

               couple                                                                           diameter    range (°C)

WPRG-N      R          Standard          RCA-2-G        Fully vinyl-covered (waterproof)    7/0.3           0 to 90              ±30          Black

WPRH-N                 Heat resistive    RCB-2-H        Fully glass-wool-covered            7/0.32          0 to 150             ±60

WPRH6-N                                                 Fully glass-wool-covered with

                                                        external shield of stainless steel

WCAG-N      K (CA)     Standard          KCC-2-G        Fully vinyl-covered (waterproof)    7/0.3           0 to 90              ±100         Blue

WCAH-N                 Heat resistive    KCB-2-H        Fully glass-wool-covered            7/0.32          0 to 150

WCAH6-N                                                 Fully glass-wool-covered with

                                                        external shield of stainless steel

WCAG-40                Heat resistive    KX-2-G         Silicone-covered                    30/0.1          −20 to 150           ±100

                       for moving parts

WICG-N      J (IC)     Standard          JX-2-G         Fully vinyl-covered (waterproof)    7/0.3           −20 to 90            ±140         Yellow

WICH-N                 Heat resistive    JX-2-H         Fully glass-wool-covered            7/0.32          0 to 150

WICH6-N                                                 Fully glass-wool-covered with

                                                        external shield of stainless steel

Note: Symbols conform to JIS standards.

        For code having duplicate exterior, check the application and check in our models.

                    ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

                    To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

                                   In the interest of product improvement, specifications are subject to change without notice.

                                                                                                                                                         31
                                                     Terms and Conditions Agreement

Read and understand this catalog.

Please read and understand this catalog before purchasing the products.                 Please consult your OMRON representative if you

have any questions or comments.

Warranties.

(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship

for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron

disclaims all other warranties, express or implied.

(b)  Limitations.      OMRON    MAKES           NO   WARRANTY          OR   REPRESENTATION,         EXPRESS             OR   IMPLIED,      ABOUT

NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER

ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE

PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.

Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the

Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at

Omron’s     election,  to  (i)  replace    (in  the  form  originally  shipped    with  Buyer  responsible  for  labor  charges  for  removal            or

replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount

equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,

repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products

were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate

modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall

not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or

electronic   components,        circuits,  system    assemblies  or    any  other  materials   or   substances   or  environments.    Any  advice,

recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above

warranty.

See http://www.omron.com/global/           or contact your Omron representative for published information.

Limitation on Liability; Etc.

OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,

LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,

WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.

Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.

Suitability of Use.

Omron     Companies    shall    not  be    responsible     for  conformity  with  any   standards,  codes   or  regulations  which  apply  to            the

combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable

third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself

is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,

system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product

with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE

QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE

OVERALL EQUIPMENT OR SYSTEM.

Programmable Products.

Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence

thereof.

Performance Data.

Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining

suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate

it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.

Change in Specifications.

Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our

practice to change part numbers when published ratings or features are changed, or when significant construction changes are

made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers

may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at

any time to confirm actual specifications of purchased Product.

Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.

                                                                                                                                           2014.10

                                                           In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation

Industrial Automation Company

http://www.ia.omron.com/                                                                       (c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory,  Delivery  &  Lifecycle  Information:

Omron:

E52-CA15AY D=1.6 2M
小广播

About Us 关于我们 客户服务 联系方式 器件索引 网站地图 最新更新 手机版

站点相关: 大学堂 TI培训 Datasheet 电子工程

北京市海淀区知春路23号集成电路设计园量子银座1305 电话:(010)82350740 邮编:100191

电子工程世界版权所有 京ICP证060456号 京ICP备10001474号 电信业务审批[2006]字第258号函 京公海网安备110108001534 Copyright © 2005-2020 sonata9.com, Inc. All rights reserved

河北11选5 幸运时时彩 亿信彩票注册 幸运时时彩 大资本平台 北京pk10 亿信彩票平台 500万彩票 500彩票网 北京pk10